Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Application of thick film segmented thermistors for measurement and analysis of ground top layer temperature profile
A new sensor for measuring ground top layer temperature profile was formed as a row of 40 thermistor segments connected in series, with which the change of temperature in the soil is mesaured and placed on 550 mm depth. The temperature sensor is multiple protected of humidity, calibrated on room temperature and placed vertically in the hole drilled on the lawn. The main electrical properties of the new sensor based on NTC thick film segmented thermistors are given in brief. The ground top layer temperature profile measurements were done in 40 points at 7am and 2 pm each day from the beginning of November 2017 to the end of February 2018.At the same time and in the same period of time the air temperature were measured and recorded. The results of measurements of ground top layer temperatureT(t,z) were given in daily and monthly diagrams as a function of time t and ground deepness d on z-axis. The correlation between ground top layer temperature profile and air temperature was analyzed: changes of ground temperature gradient and effect of precipitations on ground temperature profile. The results obtained enable study of temperature regime of ground top layer.
Application of thick film segmented thermistors for measurement and analysis of ground top layer temperature profile
A new sensor for measuring ground top layer temperature profile was formed as a row of 40 thermistor segments connected in series, with which the change of temperature in the soil is mesaured and placed on 550 mm depth. The temperature sensor is multiple protected of humidity, calibrated on room temperature and placed vertically in the hole drilled on the lawn. The main electrical properties of the new sensor based on NTC thick film segmented thermistors are given in brief. The ground top layer temperature profile measurements were done in 40 points at 7am and 2 pm each day from the beginning of November 2017 to the end of February 2018.At the same time and in the same period of time the air temperature were measured and recorded. The results of measurements of ground top layer temperatureT(t,z) were given in daily and monthly diagrams as a function of time t and ground deepness d on z-axis. The correlation between ground top layer temperature profile and air temperature was analyzed: changes of ground temperature gradient and effect of precipitations on ground temperature profile. The results obtained enable study of temperature regime of ground top layer.
Application of thick film segmented thermistors for measurement and analysis of ground top layer temperature profile
Aleksić Stanko O. (Autor:in) / Mitrović Nebojša S. (Autor:in) / Luković Miloljub D. (Autor:in) / Luković Snežana G. (Autor:in) / Obradović Nina N. (Autor:in)
2018
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Optimization and Application of NTC Thick Film Segmented Thermistors
British Library Online Contents | 2013
|Modeling of the Heat Loss in a Thermal Sensor for Water Made of NTC Thick Film Segmented Thermistors
British Library Online Contents | 2013
|Thermistors for temperature measurement in concrete
Engineering Index Backfile | 1965
|British Library Online Contents | 2006
|Composition dependent resistivity of thick film Ni(1−x)CoxMn2O4: (0≤x≤1) NTC thermistors
British Library Online Contents | 2006
|