Grade-two resistance screw shear connector behaviour for a 28 MPa concrete section
Screw shear connectors are being more commonly used in compound concrete sections in Colombia; however, they have been designed in line with Colombian Seismic-Resistant Standards (NSR-98) rather than those established for stud shear connectors. This work represents a starting point for analysing screw shear connector behaviour. 54 specimens were made for the experiment, consisting of a metallic profile and two concretes slabs where the connectors were embedded. 1/2” (12.7mm), 5/8” (15.9mm) and 3/4” (19.1mm) diameter screws were used and placed at different distances. The push-out test was used with these specimens and results were provided by using some equations for determining this type of connector’s strength in steel–concrete sections.
Grade-two resistance screw shear connector behaviour for a 28 MPa concrete section
Screw shear connectors are being more commonly used in compound concrete sections in Colombia; however, they have been designed in line with Colombian Seismic-Resistant Standards (NSR-98) rather than those established for stud shear connectors. This work represents a starting point for analysing screw shear connector behaviour. 54 specimens were made for the experiment, consisting of a metallic profile and two concretes slabs where the connectors were embedded. 1/2” (12.7mm), 5/8” (15.9mm) and 3/4” (19.1mm) diameter screws were used and placed at different distances. The push-out test was used with these specimens and results were provided by using some equations for determining this type of connector’s strength in steel–concrete sections.
Grade-two resistance screw shear connector behaviour for a 28 MPa concrete section
Sherley Larrañaga Rubio (Autor:in) / Maritzabel Molina Herrera (Autor:in)
2007
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Grade-two resistance screw shear connector behaviour for a composite section system
DOAJ | 2008
|Recombined bamboo-tapping screw wood-concrete shear connector and construction method thereof
Europäisches Patentamt | 2024
|Formulating a design for a screw-type shear connector in a compo-site section
DOAJ | 2011
|Effects of high-performance concrete on stud shear connector behaviour
British Library Conference Proceedings | 1995
|Fatigue behaviour of shear connectors in steel-concrete composite deck; Perfobond shear connector
British Library Conference Proceedings | 2007
|