Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Assessment of Ventilation Efficiency in School Classrooms Based on Indoor–Outdoor Particulate Matter and Carbon Dioxide Measurements
The concentration of indoor suspended particulate matter is considered to be one of the main factors that affect health and quality of life. In Poland, in response to the pressure of public opinion, a few thousand air purifiers have been installed in public buildings where children spend time. However, another factor that also impacts upon the quality of indoor air, namely increased CO2 mixing ratios, is frequently overlooked. The only way to remove CO2 excess from interiors is through intensive ventilation. This is often an action at odds with the need to maintain low concentrations of particulate matter in indoor air. Two methods are presented to assess the rate of air exchange using CO2 or particulate matter as a tracer. One of the methods using indoor/outdoor PM (particulate matter) concentrations is based on the use of box models for analysis. The second one uses indoor CO2 concentration change analysis. At the tested locations, they showed large deviations of the determined values of the air exchange coefficients from its limits. Both methods showed consistent ventilation parameters estimation.
Assessment of Ventilation Efficiency in School Classrooms Based on Indoor–Outdoor Particulate Matter and Carbon Dioxide Measurements
The concentration of indoor suspended particulate matter is considered to be one of the main factors that affect health and quality of life. In Poland, in response to the pressure of public opinion, a few thousand air purifiers have been installed in public buildings where children spend time. However, another factor that also impacts upon the quality of indoor air, namely increased CO2 mixing ratios, is frequently overlooked. The only way to remove CO2 excess from interiors is through intensive ventilation. This is often an action at odds with the need to maintain low concentrations of particulate matter in indoor air. Two methods are presented to assess the rate of air exchange using CO2 or particulate matter as a tracer. One of the methods using indoor/outdoor PM (particulate matter) concentrations is based on the use of box models for analysis. The second one uses indoor CO2 concentration change analysis. At the tested locations, they showed large deviations of the determined values of the air exchange coefficients from its limits. Both methods showed consistent ventilation parameters estimation.
Assessment of Ventilation Efficiency in School Classrooms Based on Indoor–Outdoor Particulate Matter and Carbon Dioxide Measurements
Jakub Bartyzel (Autor:in) / Damian Zięba (Autor:in) / Jarosław Nęcki (Autor:in) / Mirosław Zimnoch (Autor:in)
2020
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
British Library Online Contents | 2014
|Particulate matter in mechanically ventilated high school classrooms
Elsevier | 2020
|