Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Rejection of malathion by nanofiltration and reverse osmosis membranes exposed to foulant and two clean-in-place procedures
This research tested the treatment efficacy of an Energy Savings Nanofiltration 1 Low Fouling (ESNA 1-LF) nanofiltration (NF) and an Energy Saving Polyamide 2 (ESPA2) reverse osmosis (RO) membrane for removing malathion from water. Both membranes are of composite polyamide construction. The study included measuring malathion rejection using both pristine membranes and membranes exposed to a simulated secondary wastewater effluent foulant before and after two types of clean-in-place procedures. Across all conditions studied, malathion rejection ranged from 84 to 95% for the ESNA1-LF NF membrane and 77 to 94% for the ESPA2 RO membrane. Contact angle measurements were also collected for each membrane exposure condition. While the contact angle measurements indicated changes to the hydrophobicity of the selective layer of the membranes, they did not correlate to changes in the performance of malathion rejection. As expected, it was observed that malathion rejection improved with the introduction of foulant. Also, the clean-in-place procedures helped restore flux while maintaining malathion rejection. HIGHLIGHTS ENSA-1LF and ESPA2 membranes removed 77–95% of malathion from the waters studied.; Malathion rejection improved with the introduction of simulated secondary wastewater effluent foulant.; Clean-in-place procedures helped restore flux while maintaining malathion rejection.;
Rejection of malathion by nanofiltration and reverse osmosis membranes exposed to foulant and two clean-in-place procedures
This research tested the treatment efficacy of an Energy Savings Nanofiltration 1 Low Fouling (ESNA 1-LF) nanofiltration (NF) and an Energy Saving Polyamide 2 (ESPA2) reverse osmosis (RO) membrane for removing malathion from water. Both membranes are of composite polyamide construction. The study included measuring malathion rejection using both pristine membranes and membranes exposed to a simulated secondary wastewater effluent foulant before and after two types of clean-in-place procedures. Across all conditions studied, malathion rejection ranged from 84 to 95% for the ESNA1-LF NF membrane and 77 to 94% for the ESPA2 RO membrane. Contact angle measurements were also collected for each membrane exposure condition. While the contact angle measurements indicated changes to the hydrophobicity of the selective layer of the membranes, they did not correlate to changes in the performance of malathion rejection. As expected, it was observed that malathion rejection improved with the introduction of foulant. Also, the clean-in-place procedures helped restore flux while maintaining malathion rejection. HIGHLIGHTS ENSA-1LF and ESPA2 membranes removed 77–95% of malathion from the waters studied.; Malathion rejection improved with the introduction of simulated secondary wastewater effluent foulant.; Clean-in-place procedures helped restore flux while maintaining malathion rejection.;
Rejection of malathion by nanofiltration and reverse osmosis membranes exposed to foulant and two clean-in-place procedures
Anne M. Mikelonis (Autor:in) / Christopher J. Orme (Autor:in) / Amit S. Nilkar (Autor:in) / Jeffrey G. Szabo (Autor:in) / Stephen J. Reese (Autor:in)
2024
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
British Library Conference Proceedings | 2004
|Microscopy and Microanalysis of Reverse-Osmosis and Nanofiltration Membranes
British Library Online Contents | 2008
|Monitoring and control of biofouling in nanofiltration and reverse osmosis membranes
Online Contents | 2008
|Application of Nanofiltration and Reverse Osmosis Membranes for Tannery Wastewater Reuse
DOAJ | 2022
|