Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Post-peak Behaviour of Composite Column Using a Ductile Lightweight Aggregate Concrete
Abstract Oil palm shell (OPS) concrete filled steel tube (CFT) columns are acknowledged to be a new type of sustainable composite column. In this type of column, the conventional coarse aggregate was partially replaced with OPS lightweight aggregate to provide a green composite column. This type of CFT column showed higher energy absorption and flexibility compared to CFT columns with normal weight concrete. This research studied the effect of the strength of OPS concrete on the axial compressive behaviour of CFT columns for two grades of OPS concretes. The behaviour was comparable to that of CFT columns with two grades of normal concrete. The results showed that the CFT columns with OPS concrete achieved a new post-peak behaviour. The experimental results of the axial compressive load were compared with the estimation of two international standards. EC4-1994 and ACI318-14 showed a reliable and conservative estimation of the axial load capacity of CFT columns, respectively.
Post-peak Behaviour of Composite Column Using a Ductile Lightweight Aggregate Concrete
Abstract Oil palm shell (OPS) concrete filled steel tube (CFT) columns are acknowledged to be a new type of sustainable composite column. In this type of column, the conventional coarse aggregate was partially replaced with OPS lightweight aggregate to provide a green composite column. This type of CFT column showed higher energy absorption and flexibility compared to CFT columns with normal weight concrete. This research studied the effect of the strength of OPS concrete on the axial compressive behaviour of CFT columns for two grades of OPS concretes. The behaviour was comparable to that of CFT columns with two grades of normal concrete. The results showed that the CFT columns with OPS concrete achieved a new post-peak behaviour. The experimental results of the axial compressive load were compared with the estimation of two international standards. EC4-1994 and ACI318-14 showed a reliable and conservative estimation of the axial load capacity of CFT columns, respectively.
Post-peak Behaviour of Composite Column Using a Ductile Lightweight Aggregate Concrete
Mohammad Reza Hamidian (Autor:in) / Payam Shafigh (Autor:in)
2021
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Post-peak Behaviour of Composite Column Using a Ductile Lightweight Aggregate Concrete
Springer Verlag | 2021
|Ductile Response of Lightweight Aggregate Concrete Members
British Library Conference Proceedings | 2000
|Fracture Mechanical Behaviour of Lightweight Aggregate Concrete
British Library Conference Proceedings | 2004
|Fracture Mechanical Behaviour of Lightweight Aggregate Concrete
British Library Conference Proceedings | 2003
|Research on Fire Behaviour of a Lightweight Aggregate Concrete Composite Floor
British Library Conference Proceedings | 2012
|