Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Depth profile CF LIBS analysis of the wall deposited layer in the COMPASS tokamak after LiSn testing campaign
Plasma-facing materials in tokamak nuclear reactors are subject to intense heat and radiation. The design of liquid metal (LM) divertor walls has several advantages over the solid counterparts. It is important to understand the migration and re-deposition of LMs such as lithium (Li), lead (Pb) or even tin (Sn). This work presents CF LIBS depth profile analysis of the deposited layer on Ni–Cr based screws situated at different places in the COMPASS tokamak vessel during the Capillary Porous System (CPS) LM (LiSn) divertor testing campaign. The experiment was carried out at low Ar pressure (100 mbar) using ns Nd:YAG laser operating at 532 nm. The spectra were recorded using echelle spectrometer (M5000, Andor Tech.) equipped with an iCCD camera (iStar DH743, Andor Tech.). The quantification was based on observed C I, B I, Li I and (weak) Sn I lines, in addition to trace elements (Ca, Na, K) and main matrix elements (Cr, Ni, Fe). The evaluation of electron temperature and density was based on Cr I-II, Ni-II and Fe I-II lines. The LM based content is estimated to be Li (0.3-0.81 at.%) and Sn (0.1-0.23 at.%) with Li/Sn at.% ratio ranging from 3 to 3.5 (wt.% ratio of 0.17-0.20). In practise, the limit of detection of Sn by CF LIBS for this type of Cr-Ni-Fe based matrix is observed to be ∼0.1 at.%.
Depth profile CF LIBS analysis of the wall deposited layer in the COMPASS tokamak after LiSn testing campaign
Plasma-facing materials in tokamak nuclear reactors are subject to intense heat and radiation. The design of liquid metal (LM) divertor walls has several advantages over the solid counterparts. It is important to understand the migration and re-deposition of LMs such as lithium (Li), lead (Pb) or even tin (Sn). This work presents CF LIBS depth profile analysis of the deposited layer on Ni–Cr based screws situated at different places in the COMPASS tokamak vessel during the Capillary Porous System (CPS) LM (LiSn) divertor testing campaign. The experiment was carried out at low Ar pressure (100 mbar) using ns Nd:YAG laser operating at 532 nm. The spectra were recorded using echelle spectrometer (M5000, Andor Tech.) equipped with an iCCD camera (iStar DH743, Andor Tech.). The quantification was based on observed C I, B I, Li I and (weak) Sn I lines, in addition to trace elements (Ca, Na, K) and main matrix elements (Cr, Ni, Fe). The evaluation of electron temperature and density was based on Cr I-II, Ni-II and Fe I-II lines. The LM based content is estimated to be Li (0.3-0.81 at.%) and Sn (0.1-0.23 at.%) with Li/Sn at.% ratio ranging from 3 to 3.5 (wt.% ratio of 0.17-0.20). In practise, the limit of detection of Sn by CF LIBS for this type of Cr-Ni-Fe based matrix is observed to be ∼0.1 at.%.
Depth profile CF LIBS analysis of the wall deposited layer in the COMPASS tokamak after LiSn testing campaign
Sanath J. Shetty (Autor:in) / Matej Veis (Autor:in) / Sahithya Atikukke (Autor:in) / Petr Bartoň (Autor:in) / Martin Jeřáb (Autor:in) / Renaud Dejarnac (Autor:in) / Pavel Veis (Autor:in)
2023
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Elsevier | 2023
|DOAJ | 2020
|CF-LIBS quantification and depth profile analysis of Be coating mixed layers
DOAJ | 2021
|Elsevier | 2024
|