Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Seismic Behaviour of Cast-In-Situ Phosphogypsum-Reinforced Concrete Grid Frame Composite Walls
This paper mainly studies the effect of cast-in-situ phosphogypsum on seismic behaviour of reinforced concrete grid frame. The mechanical behaviour of three reinforced concrete grid frames and four cast-in-situ phosphogypsum-reinforced concrete grid frame composite walls under low cycle alternating load was designed and tested. The test results show that the reinforced concrete grid frame has less bearing capacity and poor energy consumption. The addition of cast-in-situ phosphogypsum can effectively improve the seismic behaviour of the reinforced concrete grid frame. Compared with the reinforced concrete grid frame, the bearing capacity of the cast-in-situ phosphogypsum-reinforced concrete grid frame composite wall is increased by 2-3 times, the displacement ductility coefficient is increased by 0.95∼1.2 times, and the relative accumulative energy consumption is increased by 86%∼216%. This shows that the composite wall has better bearing capacity, ductility, and energy dissipation capacity.
Seismic Behaviour of Cast-In-Situ Phosphogypsum-Reinforced Concrete Grid Frame Composite Walls
This paper mainly studies the effect of cast-in-situ phosphogypsum on seismic behaviour of reinforced concrete grid frame. The mechanical behaviour of three reinforced concrete grid frames and four cast-in-situ phosphogypsum-reinforced concrete grid frame composite walls under low cycle alternating load was designed and tested. The test results show that the reinforced concrete grid frame has less bearing capacity and poor energy consumption. The addition of cast-in-situ phosphogypsum can effectively improve the seismic behaviour of the reinforced concrete grid frame. Compared with the reinforced concrete grid frame, the bearing capacity of the cast-in-situ phosphogypsum-reinforced concrete grid frame composite wall is increased by 2-3 times, the displacement ductility coefficient is increased by 0.95∼1.2 times, and the relative accumulative energy consumption is increased by 86%∼216%. This shows that the composite wall has better bearing capacity, ductility, and energy dissipation capacity.
Seismic Behaviour of Cast-In-Situ Phosphogypsum-Reinforced Concrete Grid Frame Composite Walls
Qin Wu (Autor:in) / Huagang Zhang (Autor:in) / Hongniao Chen (Autor:in) / Xin Zhang (Autor:in) / YanHui Wei (Autor:in) / Li Li (Autor:in) / Kejian Ma (Autor:in)
2019
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Seismic behaviour of lightweight reinforced concrete shear walls
TIBKAT | 2007
|Seismic behaviour of lightweight reinforced concrete shear walls
UB Braunschweig | 2007
|Seismic Behaviour of Reinforced Concrete Slit Shear Walls Energy Dissipators
DOAJ | 2010
|Seismic behaviour of lightly reinforced concrete structural walls with openings
Online Contents | 2015
|