Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Lateral Displacement and Shear Lag Effect of Combination of Diagrid-Frame
Diagrid system, which is the portmanteau of diagonal grid member, is an exterior lateral load resisting system for tall building that has gained a wide acceptance in the design of tall buildings. There is abundance of researches that studied the efficiency of diagrid systems, which are constructed from the ground level to the top of the buildings in resisting the lateral load. Nevertheless, no study had been performed on the effectiveness of the diagrid that is constructed above other tall building systems despite the existence of a few buildings in the world that employ such system. The objective of this research is to understand the behavior of the lateral displacement and shear lag effect due to wind load when the diagrid structure is constructed above a frame. Models of 60-story buildings with a footprint of 36m x 36m were analyzed by using Staad.Pro software. The level where the diagrid members started was altered. The lateral displacement was reduced to 60.6 percent and 41 percent of the lateral displacement of a building with full frame system when the combination of frame-diagrid that had the diagrid started at Level 1 and Level 45, respectively were employed. Furthermore, the shear lag ratio was reduced from 1.7 to 1.3 when the level where the diagrid started was increased from Level 1 to Level 45.
Lateral Displacement and Shear Lag Effect of Combination of Diagrid-Frame
Diagrid system, which is the portmanteau of diagonal grid member, is an exterior lateral load resisting system for tall building that has gained a wide acceptance in the design of tall buildings. There is abundance of researches that studied the efficiency of diagrid systems, which are constructed from the ground level to the top of the buildings in resisting the lateral load. Nevertheless, no study had been performed on the effectiveness of the diagrid that is constructed above other tall building systems despite the existence of a few buildings in the world that employ such system. The objective of this research is to understand the behavior of the lateral displacement and shear lag effect due to wind load when the diagrid structure is constructed above a frame. Models of 60-story buildings with a footprint of 36m x 36m were analyzed by using Staad.Pro software. The level where the diagrid members started was altered. The lateral displacement was reduced to 60.6 percent and 41 percent of the lateral displacement of a building with full frame system when the combination of frame-diagrid that had the diagrid started at Level 1 and Level 45, respectively were employed. Furthermore, the shear lag ratio was reduced from 1.7 to 1.3 when the level where the diagrid started was increased from Level 1 to Level 45.
Lateral Displacement and Shear Lag Effect of Combination of Diagrid-Frame
Abd. Samat Roslida (Autor:in) / Chua Fong Teng (Autor:in) / Mohd Mustakim Nur Akmal Hayati (Autor:in) / Saad Sariffuddin (Autor:in) / Abu Bakar Suhaimi (Autor:in)
2018
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Anpassungsfähige Hochhaustragwerke mit Diagrid
TIBKAT | 2012
|Investigation of shear lag effect in high-rise buildings with diagrid system
DSpace@MIT | 2007
|Diagrid structures : systems, connections, details
TIBKAT | 2014
|A Review of Diagrid Systems for Lateral Load Resistance of Structures
Trans Tech Publications | 2016
|