Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
A Field Study on Thermal Comfort and Cooling Load Demand Optimization in a Tropical Climate
Energy consumption to cool an indoor environment is a substantial part of total energy end-use, particularly in a tropical climate with high energy demand for cooling. To improve energy efficiency, cooling systems can be optimized using a variety of neutral indoor temperatures to maintain a balance between an occupant’s thermal comfort and cooling energy demand. This explanatory study investigated the thermal quality and cooling energy demand of a Platinum-certified office building in the tropical climate of Malaysia. The investigation aimed to suggest a balance between occupant thermal comfort and cooling energy demand. The thermal investigation includes an objective field measurement that implements environmental equipment to monitor thermal quality and a subjective occupant’s thermal feedback using a questionnaire survey. To calculate cooling energy demand, the total equivalent temperature difference method (TETD) is applied. The results suggested an occupant’s cooling sensation of around 24 °C, with no significant difference concerning age and gender. Cooling load calculation indicated a 36% energy reduction by increasing air temperature to 26 °C, for occupants to feel thermally comfortable in a tropical climate. These findings contribute to improving sustainable energy policies, sustainable construction, and thermal comfort improvement for a tropical climate.
A Field Study on Thermal Comfort and Cooling Load Demand Optimization in a Tropical Climate
Energy consumption to cool an indoor environment is a substantial part of total energy end-use, particularly in a tropical climate with high energy demand for cooling. To improve energy efficiency, cooling systems can be optimized using a variety of neutral indoor temperatures to maintain a balance between an occupant’s thermal comfort and cooling energy demand. This explanatory study investigated the thermal quality and cooling energy demand of a Platinum-certified office building in the tropical climate of Malaysia. The investigation aimed to suggest a balance between occupant thermal comfort and cooling energy demand. The thermal investigation includes an objective field measurement that implements environmental equipment to monitor thermal quality and a subjective occupant’s thermal feedback using a questionnaire survey. To calculate cooling energy demand, the total equivalent temperature difference method (TETD) is applied. The results suggested an occupant’s cooling sensation of around 24 °C, with no significant difference concerning age and gender. Cooling load calculation indicated a 36% energy reduction by increasing air temperature to 26 °C, for occupants to feel thermally comfortable in a tropical climate. These findings contribute to improving sustainable energy policies, sustainable construction, and thermal comfort improvement for a tropical climate.
A Field Study on Thermal Comfort and Cooling Load Demand Optimization in a Tropical Climate
Masoud Esfandiari (Autor:in) / Suzaini Mohamed Zaid (Autor:in) / Muhammad Azzam Ismail (Autor:in) / Mohammad Reza Hafezi (Autor:in) / Iman Asadi (Autor:in) / Saleh Mohammadi (Autor:in)
2021
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
A field study on thermal comfort and cooling load demand optimization in a tropical climate
BASE | 2021
|Thermal environment and outdoor comfort under tropical climate
British Library Conference Proceedings | 1994
|Thermal Comfort Assessment of an Office Building in Tropical Climate Condition
DOAJ | 2018
|Evaluation of Thermal Comfort in Traditional Houses in a Tropical Climate
DOAJ | 2018
|