Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Effect of influent load fluctuation on the efficiency of vertical constructed wetlands treating dairy farm wastewater
Three vertical sub-surface flow (VSSF) constructed wetland (CW) systems (CW-1, CW-2 and CW-3) filled with different filter media, each 4 m2 in area, planted with Arundo donax was operated for 4 years for treating dairy farm wastewater. The vertical CW systems received high fluctuations in influent concentration and loads i.e. BOD (26 to 619 mg L-1 and 1.5 to 34 g m-2 d-1), TSS (165 to 643 mg L-1 and 9.1 to 24 g m-2 d-1), TP (16 to 49.9 mg L-1 and 1.2 to 2.7 g m-2 d-1) and NH4-N (24.5 to 76.2 mg L-1 and 1.3 to 4.2 g m-2 d-1) during the assessment period. Average annual removal rates showed fluctuations in removal of BOD (70.5 to 92.9%), TSS (82.5 to 97.5%), TP (51.1 to 91.9%) and NH4-N (34.6 to 69%). This shows that the removal of BOD is very sensitive to inlet load fluctuations in CWs. High inlet loads may confine good nitrification that affects ammonium-nitrogen removal while TP removal rate reduced when inlet TP loads reduced. The average concentration of the pollutants (BOD, TSS, TP and NH4-N) in the treated effluent showed noticeable decrease: 43.4 to 16.1 mg L-1 for BOD; 43.3 to 11.7 mg L-1 for TSS; 17.9 to 3.1 mg L-1 for TP and 33.2 to 22.7 mg L-1 for NH4-N. Thus from the outcomes of the current study, it can be concluded that the VSSF CW system may provide promising outcomes despite there is fluctuations in the influent loads.
Effect of influent load fluctuation on the efficiency of vertical constructed wetlands treating dairy farm wastewater
Three vertical sub-surface flow (VSSF) constructed wetland (CW) systems (CW-1, CW-2 and CW-3) filled with different filter media, each 4 m2 in area, planted with Arundo donax was operated for 4 years for treating dairy farm wastewater. The vertical CW systems received high fluctuations in influent concentration and loads i.e. BOD (26 to 619 mg L-1 and 1.5 to 34 g m-2 d-1), TSS (165 to 643 mg L-1 and 9.1 to 24 g m-2 d-1), TP (16 to 49.9 mg L-1 and 1.2 to 2.7 g m-2 d-1) and NH4-N (24.5 to 76.2 mg L-1 and 1.3 to 4.2 g m-2 d-1) during the assessment period. Average annual removal rates showed fluctuations in removal of BOD (70.5 to 92.9%), TSS (82.5 to 97.5%), TP (51.1 to 91.9%) and NH4-N (34.6 to 69%). This shows that the removal of BOD is very sensitive to inlet load fluctuations in CWs. High inlet loads may confine good nitrification that affects ammonium-nitrogen removal while TP removal rate reduced when inlet TP loads reduced. The average concentration of the pollutants (BOD, TSS, TP and NH4-N) in the treated effluent showed noticeable decrease: 43.4 to 16.1 mg L-1 for BOD; 43.3 to 11.7 mg L-1 for TSS; 17.9 to 3.1 mg L-1 for TP and 33.2 to 22.7 mg L-1 for NH4-N. Thus from the outcomes of the current study, it can be concluded that the VSSF CW system may provide promising outcomes despite there is fluctuations in the influent loads.
Effect of influent load fluctuation on the efficiency of vertical constructed wetlands treating dairy farm wastewater
Pradeep Sharma (Autor:in) / Anju Rani (Autor:in) / Deepa Minakshi (Autor:in) / Piyush Malaviya (Autor:in)
2023
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Constructed Wetlands for Dairy Wastewater Quality Improvement
British Library Conference Proceedings | 1995
|Environmental footprint of constructed wetlands treating wastewater
Online Contents | 2015
|Environmental footprint of constructed wetlands treating wastewater
Taylor & Francis Verlag | 2015
|Treating swine wastewater by integrating earthworms into constructed wetlands
Taylor & Francis Verlag | 2011
|