Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Comparative Analysis of the Performance and Study of the Effective Anchorage Length of Semi-Grouted and Fully-Grouted Sleeve Connection
Based on the insufficient data on bonding performance and effective anchorage length of sleeve grouting in assembled structure. Combining the existing studies, the sleeve grouting joint test for the static unidirectional tensile test was designed, and the influencing factors are reinforcement diameter and reinforcement anchorage length. Then, the failure mode, load-displacement relationship, energy consumption capacity and bearing capacity of the grouting sleeve connection are analysed, and the stress mechanism of the specimen in the one-way tensile state is expounded. This paper considers the actual damage state of the joint, according to the failure of the reinforcement outside the joint and the sleeve; referring to the reinforcement-concrete bond strength research theory, the effective anchorage length formula is proposed. When the steel bar is pulled out, the bond strength and bearing capacity mainly depend on the effective anchorage length. However, when the specimen breaks the steel bar outside the joint, it depends on the material performance of the steel bar itself. The research results of this paper can lay a theoretical foundation for the application of sleeve grouting joints.
Comparative Analysis of the Performance and Study of the Effective Anchorage Length of Semi-Grouted and Fully-Grouted Sleeve Connection
Based on the insufficient data on bonding performance and effective anchorage length of sleeve grouting in assembled structure. Combining the existing studies, the sleeve grouting joint test for the static unidirectional tensile test was designed, and the influencing factors are reinforcement diameter and reinforcement anchorage length. Then, the failure mode, load-displacement relationship, energy consumption capacity and bearing capacity of the grouting sleeve connection are analysed, and the stress mechanism of the specimen in the one-way tensile state is expounded. This paper considers the actual damage state of the joint, according to the failure of the reinforcement outside the joint and the sleeve; referring to the reinforcement-concrete bond strength research theory, the effective anchorage length formula is proposed. When the steel bar is pulled out, the bond strength and bearing capacity mainly depend on the effective anchorage length. However, when the specimen breaks the steel bar outside the joint, it depends on the material performance of the steel bar itself. The research results of this paper can lay a theoretical foundation for the application of sleeve grouting joints.
Comparative Analysis of the Performance and Study of the Effective Anchorage Length of Semi-Grouted and Fully-Grouted Sleeve Connection
Fenfang Yin (Autor:in) / Shiping Yin (Autor:in) / Linglei Zhang (Autor:in) / Yonggang Xu (Autor:in)
2024
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Anchorage Pull Testing for Fully Grouted Roof Bolts
NTIS | 2008
|Connection performance of restrained deformed grouted sleeve splice
SAGE Publications | 2018
|Anchorage Performance of Geopolymer-Grouted Rock Bolts
ASCE | 2022
|Behaviour of grouted sleeve connection at elevated temperature
British Library Conference Proceedings | 2001
|Experimental Study on Mechanical Properties of Half-Grouted Sleeve Connections with Grouted Defects
DOAJ | 2022
|