Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Seismic Response Analysis and Control of Frame Structures with Soft First Storey under Near-Fault Ground Motions
This paper proposes two kinds of arrangements of buckling-restrained brace dampers to strengthen soft-first-storey structures locally. Two types of near-fault ground motion, with and without pulse, were selected for a study of the seismic response characteristics of soft-first-storey structures with and without buckling-restrained brace dampers, and the effects of different bracing arrangements on improving the seismic performance of soft-first-storey structures were recognized. The results show that, compared with pulse-free ground motion, near-fault pulsed ground motion results in a more severe seismic response in soft-first-storey frame structures, leading to more serious and rapid destruction of the main structure. Buckling-restrained brace dampers have an obvious energy dissipation effect, play a better role in protecting the main structure, and have good practicality. Compared with structures in which the buckling-restrained brace dampers are arranged only on the bottommost layer, the bottom-four-layer-support structure is more advantageous in terms of seismic performance.
Seismic Response Analysis and Control of Frame Structures with Soft First Storey under Near-Fault Ground Motions
This paper proposes two kinds of arrangements of buckling-restrained brace dampers to strengthen soft-first-storey structures locally. Two types of near-fault ground motion, with and without pulse, were selected for a study of the seismic response characteristics of soft-first-storey structures with and without buckling-restrained brace dampers, and the effects of different bracing arrangements on improving the seismic performance of soft-first-storey structures were recognized. The results show that, compared with pulse-free ground motion, near-fault pulsed ground motion results in a more severe seismic response in soft-first-storey frame structures, leading to more serious and rapid destruction of the main structure. Buckling-restrained brace dampers have an obvious energy dissipation effect, play a better role in protecting the main structure, and have good practicality. Compared with structures in which the buckling-restrained brace dampers are arranged only on the bottommost layer, the bottom-four-layer-support structure is more advantageous in terms of seismic performance.
Seismic Response Analysis and Control of Frame Structures with Soft First Storey under Near-Fault Ground Motions
Chunyang Liu (Autor:in) / Peng Sun (Autor:in) / Ruofan Shi (Autor:in)
2020
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Seismic Response of Seismic Isolated Structures subject to Near Fault &Far Fault Ground Motions
DOAJ | 2022
|Probabilistic Seismic Response Analysis on Continuous Bridges Under Near-Fault Ground Motions
Springer Verlag | 2019
|A Study on the Response of Multi-Storey Buildings to Near-Fault Ground Motions
Online Contents | 2009
|A Study on the Response of Multi-Storey Buildings to Near-Fault Ground Motions
British Library Online Contents | 2009
|