Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Deuterium retention behavior in simultaneously He+–D2+ implanted tungsten
Poly-crystalline tungsten (W) samples were simultaneously irradiated with Helium (He) and Deuterium (D) ions using the triple-ion implantation device. He effect on D retention and transportation was studied using different combination of ion energies and He/D flux ratios in the simultaneous implantation. The experimental results show that D trapping at dislocation loops is significantly reduced in the case of 3 keV He+–3 keV D2+at He/D flux ratios over 0.6. D trapping by stronger trapping sites such as vacancies and vacancy clusters showed less dependence on the flux ratio. On the contrary, the D retention increases at each He/D flux ratio in the case of 3 keV He+–1 keV D2+compared to only D2+ implantation even the He/D flux ratio reaches a value of 1.0. TEM observations confirmed that dense dislocation loops are formed rather than He bubbles, which is responsible for the enhanced D retention in W. Keywords: Simultaneous implantation, D retention, Helium, Flux ratio, Transportation, Thermal desorption spectroscopy
Deuterium retention behavior in simultaneously He+–D2+ implanted tungsten
Poly-crystalline tungsten (W) samples were simultaneously irradiated with Helium (He) and Deuterium (D) ions using the triple-ion implantation device. He effect on D retention and transportation was studied using different combination of ion energies and He/D flux ratios in the simultaneous implantation. The experimental results show that D trapping at dislocation loops is significantly reduced in the case of 3 keV He+–3 keV D2+at He/D flux ratios over 0.6. D trapping by stronger trapping sites such as vacancies and vacancy clusters showed less dependence on the flux ratio. On the contrary, the D retention increases at each He/D flux ratio in the case of 3 keV He+–1 keV D2+compared to only D2+ implantation even the He/D flux ratio reaches a value of 1.0. TEM observations confirmed that dense dislocation loops are formed rather than He bubbles, which is responsible for the enhanced D retention in W. Keywords: Simultaneous implantation, D retention, Helium, Flux ratio, Transportation, Thermal desorption spectroscopy
Deuterium retention behavior in simultaneously He+–D2+ implanted tungsten
Qilai Zhou (Autor:in) / Keisuke Azuma (Autor:in) / Akihiro Togari (Autor:in) / Miyuki Yajima (Autor:in) / Masayuki Tokitani (Autor:in) / Suguru Masuzaki (Autor:in) / Naoaki Yoshida (Autor:in) / Masanori Hara (Autor:in) / Yuji Hatano (Autor:in) / Yasuhisa Oya (Autor:in)
2018
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
British Library Online Contents | 2013
|Deuterium retention in MeV self-implanted tungsten: Influence of damaging dose rate
DOAJ | 2017
|