Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Model Test Study on Natural Thawing Temperature Field of Artificial Ground Frozen Wall
In order to visualize the evolution and distribution law of the ground temperature field during artificial freezing construction, an indoor model test study was carried out based on the independently constructed hygrothermal coupling artificial ground freezing test platform. The test results show that the soil temperature in the freezing process went through the three stages of a steep drop, a slow drop, and stabilization, the earliest closure position of the frozen wall was the intermediate point between two freezing pipes, and the thickness of the frozen wall on different sections showed Section 1 > Section 2 > Section 3 after 61 min of positive freezing. The soil temperature in the natural thawing process went through the four stages of a rapid rise, short hysteresis, a second rapid rise, and a linear slow rise. By fitting the test data, the distribution function of the pipe wall temperature along the pipe length under natural thawing conditions was obtained. The research results can provide a valid basis for the numerical calculation model of a three-dimensional non-uniform natural thawing temperature field and can also provide a reference for the design of settlement grouting under natural thawing conditions.
Model Test Study on Natural Thawing Temperature Field of Artificial Ground Frozen Wall
In order to visualize the evolution and distribution law of the ground temperature field during artificial freezing construction, an indoor model test study was carried out based on the independently constructed hygrothermal coupling artificial ground freezing test platform. The test results show that the soil temperature in the freezing process went through the three stages of a steep drop, a slow drop, and stabilization, the earliest closure position of the frozen wall was the intermediate point between two freezing pipes, and the thickness of the frozen wall on different sections showed Section 1 > Section 2 > Section 3 after 61 min of positive freezing. The soil temperature in the natural thawing process went through the four stages of a rapid rise, short hysteresis, a second rapid rise, and a linear slow rise. By fitting the test data, the distribution function of the pipe wall temperature along the pipe length under natural thawing conditions was obtained. The research results can provide a valid basis for the numerical calculation model of a three-dimensional non-uniform natural thawing temperature field and can also provide a reference for the design of settlement grouting under natural thawing conditions.
Model Test Study on Natural Thawing Temperature Field of Artificial Ground Frozen Wall
Haibing Cai (Autor:in) / Longfei Yang (Autor:in) / Changqiang Pang (Autor:in) / Mengkai Li (Autor:in) / Chanrui Lu (Autor:in) / Rongbao Hong (Autor:in)
2023
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Determination of the stress field during thawing of frozen ground
Online Contents | 1979
|Duration of steam thawing of Frozen ground
Online Contents | 1978
|Some aspects of artificial thawing of frozen soils
Elsevier | 1978
|Engineering Index Backfile | 1936
|