Structural Damage of Subway Tunnel Buried Shallowly in Silt Layer under Soil Mound Loading
Based on the structural damage of the shield tunnel caused by a soil mound on the ground surface in a section of subway in Tianjin, China, the deformation and the cracking process of the segment under soil mound loading were simulated. The variations of segment, bolt, and rebar stresses with the height of the mound were analyzed. The results show that, for the stagger-jointed assembled shield tunnel that crosses the marine sedimentary silt with a burial depth of 10 m, as the mound loading increases, the damage is concentrated in the vault and hance. When the mound loading is 16.0 kPa, the segment is damaged; the crack depth and bolt axial force of the vault increase rapidly when the mound loading reaches 38.6 kPa. The analysis results are basically consistent with monitoring data. Based on the above analysis, the control standard of mound loading should be 38.6 kPa. The results of this study can provide data reference for control and structural protection of soil mound loading for similar subway tunnels.
Structural Damage of Subway Tunnel Buried Shallowly in Silt Layer under Soil Mound Loading
Based on the structural damage of the shield tunnel caused by a soil mound on the ground surface in a section of subway in Tianjin, China, the deformation and the cracking process of the segment under soil mound loading were simulated. The variations of segment, bolt, and rebar stresses with the height of the mound were analyzed. The results show that, for the stagger-jointed assembled shield tunnel that crosses the marine sedimentary silt with a burial depth of 10 m, as the mound loading increases, the damage is concentrated in the vault and hance. When the mound loading is 16.0 kPa, the segment is damaged; the crack depth and bolt axial force of the vault increase rapidly when the mound loading reaches 38.6 kPa. The analysis results are basically consistent with monitoring data. Based on the above analysis, the control standard of mound loading should be 38.6 kPa. The results of this study can provide data reference for control and structural protection of soil mound loading for similar subway tunnels.
Structural Damage of Subway Tunnel Buried Shallowly in Silt Layer under Soil Mound Loading
Xue-zeng Liu (Autor:in) / Yun-long Sang (Autor:in) / Li-min Xin (Autor:in) / Gang Shi (Autor:in) / Jian-xun Wu (Autor:in)
2020
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
DOAJ | 2023
|Monitoring the Hamburg silt mound
British Library Conference Proceedings | 1995
|Upward Pipe—Soil Interaction for Shallowly Buried Pipelines in Dense Sand
British Library Online Contents | 2018
|Shallowly-buried soft soil integrated trench reinforcing device and construction method
Europäisches Patentamt | 2015
|