Double-arm steel connector of glass façades
This paper presents a numerical analysis of a steel double-arm connector, according to the authors’ solution, designed for fixation of glass façades. The analysis was carried out in order to obtain a distribution of stresses and displacements, on the basis of which global displacements and maximum stresses were determined. An additional element of the solution was the use of the M8 bolt, as a linking element of the steel walls of both arms. The numerical simulation was performed using the ADINA program, which is based on the finite element method (FEM). The dynamic effect of wind gusts on the glass façade was assumed, taking into account both wind pressure and suction. The adoption of a rectangular element of the glass façade causes an unfavorable load distribution at the connection point. The conducted research allowed to determine displacements and stresses in a steel connector made of S355JR steel. The applicability of the proposed solution for glass façades with a height of up to 100 m has been demonstrated.
Double-arm steel connector of glass façades
This paper presents a numerical analysis of a steel double-arm connector, according to the authors’ solution, designed for fixation of glass façades. The analysis was carried out in order to obtain a distribution of stresses and displacements, on the basis of which global displacements and maximum stresses were determined. An additional element of the solution was the use of the M8 bolt, as a linking element of the steel walls of both arms. The numerical simulation was performed using the ADINA program, which is based on the finite element method (FEM). The dynamic effect of wind gusts on the glass façade was assumed, taking into account both wind pressure and suction. The adoption of a rectangular element of the glass façade causes an unfavorable load distribution at the connection point. The conducted research allowed to determine displacements and stresses in a steel connector made of S355JR steel. The applicability of the proposed solution for glass façades with a height of up to 100 m has been demonstrated.
Double-arm steel connector of glass façades
Major Izabela (Autor:in) / Major Maciej (Autor:in) / Respondek Zbigniew (Autor:in)
2019
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Glass Facades on Steel Structures
British Library Conference Proceedings | 2001
|Acoustical performances of double ventilated glass facades
Tema Archiv | 2004
|Acoustical performances of Ventilated Double Glass Facades
British Library Conference Proceedings | 2006
|Acoustical performances of ventilated double glass facades
British Library Conference Proceedings | 2005
|British Library Conference Proceedings | 2000
|