Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Effectiveness of Pollutant Removal At the Wastwewater Treatment Plant in Goleniów
The article assesses the efficiency of pollutant removal at the sewage treatment plant in Goleniów after modernization of the technological system. The extension and modernization of the existing installation resulted from the need to adapt the treatment plant to accept larger loads of pollutants, improve the parameters of treated sewage discharged to the receiver, and the poor technical condition of the equipment. Before the modernization of the treatment plant, an increase in the loads of COD, BOD5, and periodic total suspended solids in raw sewage was observed as well as a reduction in the efficiency of removing pollutants from the sewage. The efficiency of removing pollutants after modernization was in the range of BOD5 - 94.4 ÷ 99.8%, COD - 89.3 ÷ 98.9%, total suspended solids TSS - 95.3 ÷ 99.7%, total nitrogen - 64.1 ÷ 95.4%, and total phosphorus - 75.4 ÷ 99.4%.
Effectiveness of Pollutant Removal At the Wastwewater Treatment Plant in Goleniów
The article assesses the efficiency of pollutant removal at the sewage treatment plant in Goleniów after modernization of the technological system. The extension and modernization of the existing installation resulted from the need to adapt the treatment plant to accept larger loads of pollutants, improve the parameters of treated sewage discharged to the receiver, and the poor technical condition of the equipment. Before the modernization of the treatment plant, an increase in the loads of COD, BOD5, and periodic total suspended solids in raw sewage was observed as well as a reduction in the efficiency of removing pollutants from the sewage. The efficiency of removing pollutants after modernization was in the range of BOD5 - 94.4 ÷ 99.8%, COD - 89.3 ÷ 98.9%, total suspended solids TSS - 95.3 ÷ 99.7%, total nitrogen - 64.1 ÷ 95.4%, and total phosphorus - 75.4 ÷ 99.4%.
Effectiveness of Pollutant Removal At the Wastwewater Treatment Plant in Goleniów
Jakubaszek Anita (Autor:in)
2021
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Modeling Pollutant Removal Effectiveness of BMP's
British Library Conference Proceedings | 1993
|Air Change Effectiveness and Pollutant Removal Efficiency during Adverse Mixing Conditions
Wiley | 1997
|BMP Pollutant Removal Efficiency
British Library Conference Proceedings | 2008
|Effects on air pollutant removal by plant absorption and adsorption
British Library Online Contents | 2005
|Effects on air pollutant removal by plant absorption and adsorption
Online Contents | 2005