Comparative Analysis of CIBSE Admittance and ASHRAE Radiant Time Series Cooling Load Models
Due to the impacts of carbon emissions on climate change and the expected dramatic increase in global cooling demand by 2050, it is of a paramount importance that the required energy to cool buildings is accurately predicted. This ensures that equipment is appropriately sized, which ultimately reduces energy consumption and global carbon emissions. CIBSE and ASHRAE standards are both widely adopted for cooling load predictions, but they adopt different calculation methods, with CIBSE adopting admittance and ASHRAE adopting radiant time series (RTS), which produce significantly different results in cooling load. This study comparatively and qualitatively evaluates the CIBSE admittance and ASHRAE RTS cooling load models by analysing their structures and key input parameters for a mock-up building to identify inconsistencies between the two methods. There were flaws within both models that resulted in the CIBSE method underpredicting the cooling load, whereas the ASHRAE method typically overpredicting it. This resulted in a maximal average difference of over 60%. The substantial predicted cooling load difference was mainly caused by the ASHRAE RTS model, which was highly receptive to solar gains, and it consequently led to overprediction in cooling load when compared to the CIBSE admittance model.
Comparative Analysis of CIBSE Admittance and ASHRAE Radiant Time Series Cooling Load Models
Due to the impacts of carbon emissions on climate change and the expected dramatic increase in global cooling demand by 2050, it is of a paramount importance that the required energy to cool buildings is accurately predicted. This ensures that equipment is appropriately sized, which ultimately reduces energy consumption and global carbon emissions. CIBSE and ASHRAE standards are both widely adopted for cooling load predictions, but they adopt different calculation methods, with CIBSE adopting admittance and ASHRAE adopting radiant time series (RTS), which produce significantly different results in cooling load. This study comparatively and qualitatively evaluates the CIBSE admittance and ASHRAE RTS cooling load models by analysing their structures and key input parameters for a mock-up building to identify inconsistencies between the two methods. There were flaws within both models that resulted in the CIBSE method underpredicting the cooling load, whereas the ASHRAE method typically overpredicting it. This resulted in a maximal average difference of over 60%. The substantial predicted cooling load difference was mainly caused by the ASHRAE RTS model, which was highly receptive to solar gains, and it consequently led to overprediction in cooling load when compared to the CIBSE admittance model.
Comparative Analysis of CIBSE Admittance and ASHRAE Radiant Time Series Cooling Load Models
Ryan Hepple (Autor:in) / Siliang Yang (Autor:in) / Sanober Khattak (Autor:in) / Zi Qian (Autor:in) / Deo Prasad (Autor:in)
2022
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
CIBSE - CIBSE news - The special relationship with ASHRAE
Online Contents | 2007
CIBSE - CIBSE news - Last chance to book for CIBSE-ASHRAE conference
Online Contents | 2008
CIBSE - CIBSE news - Booking details for annual dinner -- And the CIBSE-ASHRAE conference
Online Contents | 2008
News analysis - CIBSE-ASHRAE conference round-up
Online Contents | 2008
CIBSE - CIBSE news - A report on the CIBSE ANZ Region
Online Contents | 2007