Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Application of Stage-Fall-Discharge Rating Curves to a Reservoir Based on Acoustic Doppler Velocity Meter Measurement Data
The applicability of the stage-fall-discharge (SFD) method in combination with acoustic Doppler velocity meter (ADVM) data, upstream of a hydraulic structure, specifically, the Sejong-weir located in the Geum River, Korea, was examined. We developed three rating curves: a conventional simple rating curve with the data measured using an acoustic Doppler current profiler (ADCP) and floating objects, an SFD rating curve with the data measured using the ADCP and floating objects, and an SFD rating curve with the data measured using an ADVM. Because of the gate operation effect, every rating curve involved many uncertainties under 1000 m3/s (3.13 m2/s, specific discharge). In terms of the hydrograph reconstruction, compared with the conventional simple rating curve, the SFD developed using ADVM data exhibited a higher agreement with the measured data in terms of the pattern. Furthermore, the measured discharge over 1000 m3/s primarily ranged between 97.5% and 2.5% in the graph comparing the ratio of the median and observed discharge. Based on this experiment, it is confirmed that the SFD rating curve with data to represent the backwater effect, such as ADVM data, can reduce the uncertainties induced by the typical rating curve
Application of Stage-Fall-Discharge Rating Curves to a Reservoir Based on Acoustic Doppler Velocity Meter Measurement Data
The applicability of the stage-fall-discharge (SFD) method in combination with acoustic Doppler velocity meter (ADVM) data, upstream of a hydraulic structure, specifically, the Sejong-weir located in the Geum River, Korea, was examined. We developed three rating curves: a conventional simple rating curve with the data measured using an acoustic Doppler current profiler (ADCP) and floating objects, an SFD rating curve with the data measured using the ADCP and floating objects, and an SFD rating curve with the data measured using an ADVM. Because of the gate operation effect, every rating curve involved many uncertainties under 1000 m3/s (3.13 m2/s, specific discharge). In terms of the hydrograph reconstruction, compared with the conventional simple rating curve, the SFD developed using ADVM data exhibited a higher agreement with the measured data in terms of the pattern. Furthermore, the measured discharge over 1000 m3/s primarily ranged between 97.5% and 2.5% in the graph comparing the ratio of the median and observed discharge. Based on this experiment, it is confirmed that the SFD rating curve with data to represent the backwater effect, such as ADVM data, can reduce the uncertainties induced by the typical rating curve
Application of Stage-Fall-Discharge Rating Curves to a Reservoir Based on Acoustic Doppler Velocity Meter Measurement Data
Yeonsu Kim (Autor:in) / Sungryul Oh (Autor:in) / Seungsoo Lee (Autor:in) / Jisun Byun (Autor:in) / Hyunuk An (Autor:in)
2021
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Prediction of Discontinuity in Stage-Discharge Rating Curves
British Library Online Contents | 1998
|Prediction of Discontinuity in Stage-Discharge Rating Curves
Online Contents | 1998
|Acoustic Doppler Current Meter: Shallow Water Harbor Application
British Library Online Contents | 1995
|Influence of One Line Vegetation on Stage-Discharge Rating Curves in Compound Channel
British Library Conference Proceedings | 2009
|