Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Pullout performance of steel bars partially bonded in concrete with epoxy resin
Abstract The installation of new reinforcing bars onto an existing structure is a common practice in civil construction both for old and new structures. The use of anchors has been extensively studied and normalized. The placement of steel reinforcement bars in holes filled with epoxy resin, despite their wide use, still lacks a satisfactory methodology for the design of such systems. In this context, the aim of this paper is to present the results of an experimental programme for confined pullout tests, comparing the performance of cast steel reinforcement bars to that of bars bonded to concrete with epoxy resin. The investigated test parameters included the bar diameter, the embedment length and the resin thickness. Tests results showed a significant efficiency of epoxy resin as structural bonding agent and allowed the verification of sizeable reduction in the anchorage lengths for bonded bars.
Pullout performance of steel bars partially bonded in concrete with epoxy resin
Abstract The installation of new reinforcing bars onto an existing structure is a common practice in civil construction both for old and new structures. The use of anchors has been extensively studied and normalized. The placement of steel reinforcement bars in holes filled with epoxy resin, despite their wide use, still lacks a satisfactory methodology for the design of such systems. In this context, the aim of this paper is to present the results of an experimental programme for confined pullout tests, comparing the performance of cast steel reinforcement bars to that of bars bonded to concrete with epoxy resin. The investigated test parameters included the bar diameter, the embedment length and the resin thickness. Tests results showed a significant efficiency of epoxy resin as structural bonding agent and allowed the verification of sizeable reduction in the anchorage lengths for bonded bars.
Pullout performance of steel bars partially bonded in concrete with epoxy resin
R. H. SOUZA (Autor:in) / M. E. TAVARES (Autor:in) / D. V. FERNANDES (Autor:in)
2018
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Pullout Performance of Fully and Partially Bonded Retrofit Anchors in Low-Strength Concrete
Online Contents | 2011
|Pullout Behaviour of Bars in Concrete Confined with Post-tensioned Steel Straps
Springer Verlag | 2022
|Measurement of concrete strength by embedded pullout bars
Engineering Index Backfile | 1944
|PULLOUT TESTS OF NSM - FRP BARS IN CONCRETE
British Library Conference Proceedings | 2005
|Measurement of concrete strength by embedded pullout bars
Engineering Index Backfile | 1944
|