Stiffening effects-controlling sizing procedure of ADAS dampers in seismic retrofit of frame structures
Added Damping and Stiffness (ADAS) steel dissipators are among the most classical devices installed in dissipative bracing systems for the advanced seismic retrofit of frame buildings. An energy-based sizing procedure is formulated in this study for this class of dampers, where the total number of constituting plates is directly related, without iterative steps, to the supplementary damping energy required to jointly reduce stress states in structural members and storey drifts. The stiffening effects of the dissipative braces are expressly controlled, so as to compensate for the increase in storey shears induced by their incorporation in the frame skeleton. The sizing procedure is demonstratively applied to the retrofit design of a 6-storey reinforced concrete building, to explicate and discuss the use of its analytical relations and relevant limitations in practice. The evaluation of the seismic performance of the structure in retrofitted conditions allows comparing the response of the dissipative bracing system with the hypotheses formulated at the sizing stage.
Stiffening effects-controlling sizing procedure of ADAS dampers in seismic retrofit of frame structures
Added Damping and Stiffness (ADAS) steel dissipators are among the most classical devices installed in dissipative bracing systems for the advanced seismic retrofit of frame buildings. An energy-based sizing procedure is formulated in this study for this class of dampers, where the total number of constituting plates is directly related, without iterative steps, to the supplementary damping energy required to jointly reduce stress states in structural members and storey drifts. The stiffening effects of the dissipative braces are expressly controlled, so as to compensate for the increase in storey shears induced by their incorporation in the frame skeleton. The sizing procedure is demonstratively applied to the retrofit design of a 6-storey reinforced concrete building, to explicate and discuss the use of its analytical relations and relevant limitations in practice. The evaluation of the seismic performance of the structure in retrofitted conditions allows comparing the response of the dissipative bracing system with the hypotheses formulated at the sizing stage.
Stiffening effects-controlling sizing procedure of ADAS dampers in seismic retrofit of frame structures
Gloria Terenzi (Autor:in) / Stefano Sorace (Autor:in) / Elena Fuso (Autor:in)
2023
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
BASE | 2023
|Seismic Retrofit Method for Building Structures with Seismic Retrofit Dampers
Europäisches Patentamt | 2021
|Seismic Retrofit of Moment Resisting Frame with Viscoelastic Dampers
British Library Conference Proceedings | 1995
|Seismic retrofit of structures using steel honeycomb dampers
Springer Verlag | 2017
|Seismic retrofit of structures using steel honeycomb dampers
Online Contents | 2017
|