Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
An Assessment of the Performance of the Amasya Bayezid II Mosque Under Static and Dynamic Loads
Located in the north-central part of Anatolia, Amasya has hosted many civilizations throughout history. The city existed as a major commercial and cultural center during the Byzantine, Seljuk, and Ottoman eras. Many monumental works were gifted by these civilizations to the city, including the Bayezid II Mosque, which was constructed during the Ottoman Empire. In this study, the Bayezid II Mosque was assessed under static and dynamic loads. Results from the static analyses revealed the sections where stress and deformations occurred under static loads. Iron braces were used in these parts to reduce these impacts. Results from the dynamic analyses indicated that the sections of the structure where stresses and deformations have large values are the domes, the minarets, narthex, and the bottom and top points of the columns in the main load-bearing unit. The data derived from this study can serve to guide future restoration efforts.
An Assessment of the Performance of the Amasya Bayezid II Mosque Under Static and Dynamic Loads
Located in the north-central part of Anatolia, Amasya has hosted many civilizations throughout history. The city existed as a major commercial and cultural center during the Byzantine, Seljuk, and Ottoman eras. Many monumental works were gifted by these civilizations to the city, including the Bayezid II Mosque, which was constructed during the Ottoman Empire. In this study, the Bayezid II Mosque was assessed under static and dynamic loads. Results from the static analyses revealed the sections where stress and deformations occurred under static loads. Iron braces were used in these parts to reduce these impacts. Results from the dynamic analyses indicated that the sections of the structure where stresses and deformations have large values are the domes, the minarets, narthex, and the bottom and top points of the columns in the main load-bearing unit. The data derived from this study can serve to guide future restoration efforts.
An Assessment of the Performance of the Amasya Bayezid II Mosque Under Static and Dynamic Loads
Şeker B. Ş. (Autor:in) / Büyükgüner Gizem (Autor:in)
2021
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Amasya-Gokmedrese mosque, Some new conceptions
British Library Conference Proceedings | 1999
|Determination of Greenway Routes Using Network Analysis in Amasya, Turkey
Online Contents | 2016
|New strengthening approach of Mustafa Pasha Mosque to seismic loads
British Library Conference Proceedings | 2009
|Earthquake performance of Suleymaniye mosque
British Library Conference Proceedings | 2002
|