Multi-Zone Energy Performance Assessment of Algerian Social Housing Using a Parametric Approach
In the early stages of building design, decisions are made about the building’s form and envelope, but designers rarely base their decisions on sophisticated energy simulations, even though these features are critical to a building’s energy performance. This paper employs three methods—empirical, parametric, and uncertainty—to assess the interconnectedness of building form, envelope, orientation, and occupancy regarding thermal comfort and energy consumption for heating and cooling a residential building across three regions: Gdyel (mediterranean climate), Oum El Bouaghi, and Constantine (semi-arid climate). The study variables include indoor air temperature, relative humidity, and energy consumption. The initial findings stem from an experiment conducted in an apartment on the top floor of a building in Gdyel, which allowed us to record the evolution of the variables mentioned throughout the year and validate the parametric results of the multi-zone model created in TRNSYS16 software. This study showed that for the considered climates, a compact form is more suitable; it was found that the top floor with SF = 0.57 needs about 30% to 54% more energy than the inter-floor with SF = 0.21. In addition, the heating and cooling methods and habits adopted by Algerian households are responsible for 18% to 35% on the top floor and the inter-floor, respectively.
Multi-Zone Energy Performance Assessment of Algerian Social Housing Using a Parametric Approach
In the early stages of building design, decisions are made about the building’s form and envelope, but designers rarely base their decisions on sophisticated energy simulations, even though these features are critical to a building’s energy performance. This paper employs three methods—empirical, parametric, and uncertainty—to assess the interconnectedness of building form, envelope, orientation, and occupancy regarding thermal comfort and energy consumption for heating and cooling a residential building across three regions: Gdyel (mediterranean climate), Oum El Bouaghi, and Constantine (semi-arid climate). The study variables include indoor air temperature, relative humidity, and energy consumption. The initial findings stem from an experiment conducted in an apartment on the top floor of a building in Gdyel, which allowed us to record the evolution of the variables mentioned throughout the year and validate the parametric results of the multi-zone model created in TRNSYS16 software. This study showed that for the considered climates, a compact form is more suitable; it was found that the top floor with SF = 0.57 needs about 30% to 54% more energy than the inter-floor with SF = 0.21. In addition, the heating and cooling methods and habits adopted by Algerian households are responsible for 18% to 35% on the top floor and the inter-floor, respectively.
Multi-Zone Energy Performance Assessment of Algerian Social Housing Using a Parametric Approach
Ikram Hadji (Autor:in) / Said Mazouz (Autor:in) / Abderrahmane Mejedoub Mokhtari (Autor:in) / Mohammed-Hichem Benzaama (Autor:in) / Yassine El Mendili (Autor:in)
2024
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
The impact of building modifications on Algerian social collective housing
Taylor & Francis Verlag | 2014
|Parametric Approach to Simplified Life Cycle Assessment of Social Housing Projects
DOAJ | 2022
|Algerian Housing Policies, Practices and End Product
Online Contents | 1993
|British Library Conference Proceedings | 2008
|Development of an integrated approach for Algerian building seismic damage assessment
British Library Online Contents | 2013
|