Bolt Spacing and End Distance of Bolted Connection of Laminated Veneer Lumber (LVL) Sengon
This paper focuses on bolt connections on Laminated Veneer Lumber (LVL) Sengon. Series of connection tests were conducted to evaluate 3.5d, 5d, and 7d end distances and 3d, 4d, and 5d bolt spacings, where d is a 10 mm bolt diameter. All connections were double-shear model (steel-LVL-steel). The results showed that all variations of end distance failed in ductile manner especially the connections with end distances of 5d and 7d. Load carrying capacity of the connections with end distances of 5d and 7d were about the same. For single bolt connections, those with 5d bolt spacing had the highest ratio of load carrying capacity. Only the two-bolt connections with 5d bolt spacing gave the ratio of load carrying capacity higher than that of prediction. These findings therefore suggests that minimum end distance of 5d and minimum bolt spacing of 5d are recommended to be addopted in LVL Sengon bolted connections.
Bolt Spacing and End Distance of Bolted Connection of Laminated Veneer Lumber (LVL) Sengon
This paper focuses on bolt connections on Laminated Veneer Lumber (LVL) Sengon. Series of connection tests were conducted to evaluate 3.5d, 5d, and 7d end distances and 3d, 4d, and 5d bolt spacings, where d is a 10 mm bolt diameter. All connections were double-shear model (steel-LVL-steel). The results showed that all variations of end distance failed in ductile manner especially the connections with end distances of 5d and 7d. Load carrying capacity of the connections with end distances of 5d and 7d were about the same. For single bolt connections, those with 5d bolt spacing had the highest ratio of load carrying capacity. Only the two-bolt connections with 5d bolt spacing gave the ratio of load carrying capacity higher than that of prediction. These findings therefore suggests that minimum end distance of 5d and minimum bolt spacing of 5d are recommended to be addopted in LVL Sengon bolted connections.
Bolt Spacing and End Distance of Bolted Connection of Laminated Veneer Lumber (LVL) Sengon
Ali Awaludin (Autor:in) / Dani Nugroho Saputro (Autor:in)
2017
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Bolt Spacing and End Distance of Bolted Connection of Laminated Veneer Lumber (LVL) Sengon
DOAJ | 2017
|Laminated Veneer Lumber (LVL) Sengon: An Innovative Sustainable Building Material in Indonesia
BASE | 2018
|Nonlinear Finite Element Analysis of Flexural Laminated Veneer Lumber (LVL) Sengon Slender Beam
DOAJ | 2022
|Fire performance of bolted connections in laminated veneer lumber
British Library Online Contents | 2009
|Fire performance of bolted connections in laminated veneer lumber
Online Contents | 2009
|