The Influence Range of Solar Radiation on the Indoor Radiant Thermal Environment
In glass curtain wall buildings, the solar radiation irradiation depth is greater, more solar radiation heat gain also has a greater impact on the indoor thermal environment. In the traditional air-conditioning system design, the inner and outer zoning of air-conditioning often relies on engineering experience and is not applicable to glass curtain wall buildings, therefore, it is necessary to propose a new method of internal and external zoning for glass curtain wall buildings. In this paper, the distribution of solar radiation in the room throughout the year is analysed to clarify the depth of solar radiation in the room and the influence range on the indoor radiant thermal environment. The results show that the influence range of solar radiation in the south-oriented room is 2m in summer and 3m in winter, and the influence range of solar radiation in the east and west oriented room is 3m in summer and about 2.5m in winter. The results of this paper provide a theoretical basis for the delineation of the inner and outer zones of buildings with glass curtain walls, which can reduce the thermal discomfort of the people in the room and the energy consumption.
The Influence Range of Solar Radiation on the Indoor Radiant Thermal Environment
In glass curtain wall buildings, the solar radiation irradiation depth is greater, more solar radiation heat gain also has a greater impact on the indoor thermal environment. In the traditional air-conditioning system design, the inner and outer zoning of air-conditioning often relies on engineering experience and is not applicable to glass curtain wall buildings, therefore, it is necessary to propose a new method of internal and external zoning for glass curtain wall buildings. In this paper, the distribution of solar radiation in the room throughout the year is analysed to clarify the depth of solar radiation in the room and the influence range on the indoor radiant thermal environment. The results show that the influence range of solar radiation in the south-oriented room is 2m in summer and 3m in winter, and the influence range of solar radiation in the east and west oriented room is 3m in summer and about 2.5m in winter. The results of this paper provide a theoretical basis for the delineation of the inner and outer zones of buildings with glass curtain walls, which can reduce the thermal discomfort of the people in the room and the energy consumption.
The Influence Range of Solar Radiation on the Indoor Radiant Thermal Environment
Lu Shunyao (Autor:in) / Yang Dongfang (Autor:in) / Huang Xiaoqing (Autor:in) / Chen Tao (Autor:in)
2025
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
British Library Online Contents | 2017
|Design Range of Indoor Relative Humidity in Radiant Cooling Environment
British Library Conference Proceedings | 2011
|IMPROVING THE INDOOR THERMAL ENVIRONMENT WITH CEILING RADIANT TERMINALS
TIBKAT | 2021
|Improving the indoor thermal environment with ceiling radiant terminals
BASE | 2021
|Experimental Investigation of Indoor Thermal Environment of Using Radiant Cooling
British Library Conference Proceedings | 2011
|