Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Kajian Eksperimen Kuat Tekan Beton Ringan Menggunakan Agregat Bambu dan Bahan Tambah Beton
The use bamboo as a substitute aggregate is an effort to reduce the density and static load of structural elements. This reseach focuses on the problem related to the specific gravity and compressive strength of the use of bamboo as a lightweight concrete aggregate. Specimens were produced using additive and 10 mm maximum grain size of bamboo agregate as a substitute for split aggregate, in a lightweight concrete composite systems. Variation of bamboo content as a substitute aggregate were selected being 0% (normal), 20%, 40%, 60%, 80% and 100% by weight of split aggregate. The samples are in the form of cylinder (of 15 cm diameter and 30 cm height), while the compression testing were performed after 14 days of treatment. The results showed that the lightweight concrete containing 80% of bamboo aggregate possessing compressive strength 5,86 MPa, which is below the minimum standard of ACI of 17,2 MPa.
Kajian Eksperimen Kuat Tekan Beton Ringan Menggunakan Agregat Bambu dan Bahan Tambah Beton
The use bamboo as a substitute aggregate is an effort to reduce the density and static load of structural elements. This reseach focuses on the problem related to the specific gravity and compressive strength of the use of bamboo as a lightweight concrete aggregate. Specimens were produced using additive and 10 mm maximum grain size of bamboo agregate as a substitute for split aggregate, in a lightweight concrete composite systems. Variation of bamboo content as a substitute aggregate were selected being 0% (normal), 20%, 40%, 60%, 80% and 100% by weight of split aggregate. The samples are in the form of cylinder (of 15 cm diameter and 30 cm height), while the compression testing were performed after 14 days of treatment. The results showed that the lightweight concrete containing 80% of bamboo aggregate possessing compressive strength 5,86 MPa, which is below the minimum standard of ACI of 17,2 MPa.
Kajian Eksperimen Kuat Tekan Beton Ringan Menggunakan Agregat Bambu dan Bahan Tambah Beton
Muhammad Riang Endarto (Autor:in) / Muhammad Heri Zulfiar (Autor:in)
2016
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Pengaruh Penggunaan Bambu Sebagai Pengganti Agregat Split terhadap Kuat Tekan Beton Ringan
DOAJ | 2016
|PEMANFAATAN SERBUK KACA SEBAGAI BAHAN TAMBAH AGREGAT HALUS UNTUK MENINGKATKAN KUAT TEKAN BETON
BASE | 2015
|Analisis Perbandingan Kuat Tekan Beton Ringan Menggunakan Agregat Halus Dari Beberapa Lokasi Quarry
BASE | 2021
|Limbah Bata Ringan untuk Bahan Campuran Agregat Halus Terhadap Kuat Tekan Pada Beton K-250
BASE | 2021
|