Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Corrosion as a cause of the failure of the pipeline steel supporting structure
The article describes the failure of the steel supporting structure of the pipeline caused by corrosion. The structure in question is a three-span steel bridge with truss girders. The structure was erected in the 1960s and is located above the railway track. Due to the specific shape of the hinges, which join the middle span with the rest of the structure one of them was damaged by corrosion, which caused it to break off. That led to situation where the middle span was retained by only three joints. To achieve proper safety of the structure it was additionally supported and strengthened. Due to the necessity of quick repair (there was a real threat of a collapse), some of the works performed had a provisional character. The article presents a description, detailed causes for failure and all the works, which were carried out in order to protect and repair the structure. The analysis of this case showed that, despite adequate protection of structural elements against corrosion, improper design resulting in retaining water led to serious failure.
Corrosion as a cause of the failure of the pipeline steel supporting structure
The article describes the failure of the steel supporting structure of the pipeline caused by corrosion. The structure in question is a three-span steel bridge with truss girders. The structure was erected in the 1960s and is located above the railway track. Due to the specific shape of the hinges, which join the middle span with the rest of the structure one of them was damaged by corrosion, which caused it to break off. That led to situation where the middle span was retained by only three joints. To achieve proper safety of the structure it was additionally supported and strengthened. Due to the necessity of quick repair (there was a real threat of a collapse), some of the works performed had a provisional character. The article presents a description, detailed causes for failure and all the works, which were carried out in order to protect and repair the structure. The analysis of this case showed that, despite adequate protection of structural elements against corrosion, improper design resulting in retaining water led to serious failure.
Corrosion as a cause of the failure of the pipeline steel supporting structure
Paczkowski Wiesław (Autor:in) / Skibicki Szymon (Autor:in)
2019
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Corrosion Cause of a Subsea Pipeline
British Library Online Contents | 2017
|NTSB Determines Likely Cause of Pipeline Failure
British Library Online Contents | 2001
|Localized Corrosion Failure of Type 316 Stainless Steel Drain Pipeline
British Library Online Contents | 2016
|Failure Avoidance-Corrosion Inhibitor Can Cause Corrosion
British Library Online Contents | 1993
|Corrosion Failure Analysis on Water Pipeline
British Library Online Contents | 2013
|