Numerical analysis on wind-induced vibration response of long-span transmission tower-line system
Based on the engineering background related to ±800 kV ultra-high voltage (UHV) transmission lines spanning the Yellow River, finite element models were developed for single-tower and transmission tower-line systems, with their wind-induced responses under wind loads were simulated and analysed. In addition, the coupling effect in a large-span transmission tower line system was investigated. The results showed that the natural vibration frequency of the tower-line system was slightly lower than that of a single tower and that the torsional natural frequency was the most significantly reduced. The transmission tower-line system has a maximum displacement of 1.92 times that of a single tower when the wind angle is 0°. The maximum axial force and stress in the tower-line system are 1.6 times and 1.37 times higher than those in a single tower. The interaction between the tower and wires significantly affects the wind-induced response of the tower body. Hence, considering the dynamic coupling effect of the tower-line transmission system is important when designing a tower.
Numerical analysis on wind-induced vibration response of long-span transmission tower-line system
Based on the engineering background related to ±800 kV ultra-high voltage (UHV) transmission lines spanning the Yellow River, finite element models were developed for single-tower and transmission tower-line systems, with their wind-induced responses under wind loads were simulated and analysed. In addition, the coupling effect in a large-span transmission tower line system was investigated. The results showed that the natural vibration frequency of the tower-line system was slightly lower than that of a single tower and that the torsional natural frequency was the most significantly reduced. The transmission tower-line system has a maximum displacement of 1.92 times that of a single tower when the wind angle is 0°. The maximum axial force and stress in the tower-line system are 1.6 times and 1.37 times higher than those in a single tower. The interaction between the tower and wires significantly affects the wind-induced response of the tower body. Hence, considering the dynamic coupling effect of the tower-line transmission system is important when designing a tower.
Numerical analysis on wind-induced vibration response of long-span transmission tower-line system
Xianxin Li (Autor:in) / Binghao Ding (Autor:in) / Daokun Qi (Autor:in) / Kaixin Zhang (Autor:in) / Miaomiao Wang (Autor:in)
2024
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Rain-Wind-Induced Vibration Control for Long Span Transmission Tower
Tema Archiv | 2012
|Fragility analysis of a long-span transmission tower–line system under wind loads
SAGE Publications | 2020
|Dynamic Response analysis of Long Span Transmission Tower under Tornado
Tema Archiv | 2012
|