In winter, people's demand for heating is stronger and stronger in southern China, and the floor radiant heating system is more and more popular. However, there are no suitable guidelines or standards for the floor temperature of the heating system in this area. The insulation performance of buildings in southern is not as good as other area which have central heating system. So the acceptable floor temperature suitable for this area needed to be studied.12 healthy college students participated as samples in this experiment. The floor surface temperature was controlled by varying the temperature of water flowing underneath the floor. The main conclusions were as follows: 1) the floor surface temperature directly affected the skin temperature of the foot and the thermal comfort of the foot. There was a significant statistical relationship between the floor surface temperature and the overall thermal sensation. 2) The acceptable floor temperature ranged from 26.1 °C to 34.3 °C for sitting positions and 24.6 °C ~34.7 °C for standing positions. 3) Considering the head thermal comfort and the health effects of the cumulative effect of long-term heat exposure, the recommended upper limit of the floor temperature in this experiment is 31°C.
In winter, people's demand for heating is stronger and stronger in southern China, and the floor radiant heating system is more and more popular. However, there are no suitable guidelines or standards for the floor temperature of the heating system in this area. The insulation performance of buildings in southern is not as good as other area which have central heating system. So the acceptable floor temperature suitable for this area needed to be studied.12 healthy college students participated as samples in this experiment. The floor surface temperature was controlled by varying the temperature of water flowing underneath the floor. The main conclusions were as follows: 1) the floor surface temperature directly affected the skin temperature of the foot and the thermal comfort of the foot. There was a significant statistical relationship between the floor surface temperature and the overall thermal sensation. 2) The acceptable floor temperature ranged from 26.1 °C to 34.3 °C for sitting positions and 24.6 °C ~34.7 °C for standing positions. 3) Considering the head thermal comfort and the health effects of the cumulative effect of long-term heat exposure, the recommended upper limit of the floor temperature in this experiment is 31°C.
Acceptable surface temperature of floor radiant heating system based on thermal comfort study in southern China
2019
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Radiant Heating for Thermal Comfort
British Library Online Contents | 1996
|TIBKAT | 1999
|Permissible floor temperature for radiant heating
Engineering Index Backfile | 1954
|Temperature distribution in radiant floor heating
Engineering Index Backfile | 1947
|