Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Assessment of the Thermo-Hydraulic Efficiency of an Indoor-Designed Jet Impingement Solar Thermal Collector Roughened with Single Discrete Arc-Shaped Ribs
This study illustrates the impact of single discrete arc-shaped ribs (SDASR)-type artificial roughness on the performance of a jet impingement solar thermal collector (JISTC). The impact of parametric variations of SDASR on the Nusselt number , friction factor , and thermohydraulic performance is examined. The spacer length () of the SDASR was changed from 0 mm to 300 mm in stages of 100 mm during the experiment. The fixed parameters of the SDASR were a relative discrete distance of 0.67, relative discrete width of 0.87, relative rib height of 0.047, relative rib pitch of 1.7, angle of an arc of 60°, jet diameter ratio of 0.065, streamwise pitch ratio of 1.72, and spanwise pitch ratio of 0.82. The Reynolds number was altered from 3000 to 19,000. The and of a JISTC with a roughened absorber plate was found to be enhanced by 5.25 and 5.98 times as compared to an STC without artificial roughness. The optimal findings of , and were achieved at = 0 mm. The maximum value of the obtained at = 0 mm was 2.9.
Assessment of the Thermo-Hydraulic Efficiency of an Indoor-Designed Jet Impingement Solar Thermal Collector Roughened with Single Discrete Arc-Shaped Ribs
This study illustrates the impact of single discrete arc-shaped ribs (SDASR)-type artificial roughness on the performance of a jet impingement solar thermal collector (JISTC). The impact of parametric variations of SDASR on the Nusselt number , friction factor , and thermohydraulic performance is examined. The spacer length () of the SDASR was changed from 0 mm to 300 mm in stages of 100 mm during the experiment. The fixed parameters of the SDASR were a relative discrete distance of 0.67, relative discrete width of 0.87, relative rib height of 0.047, relative rib pitch of 1.7, angle of an arc of 60°, jet diameter ratio of 0.065, streamwise pitch ratio of 1.72, and spanwise pitch ratio of 0.82. The Reynolds number was altered from 3000 to 19,000. The and of a JISTC with a roughened absorber plate was found to be enhanced by 5.25 and 5.98 times as compared to an STC without artificial roughness. The optimal findings of , and were achieved at = 0 mm. The maximum value of the obtained at = 0 mm was 2.9.
Assessment of the Thermo-Hydraulic Efficiency of an Indoor-Designed Jet Impingement Solar Thermal Collector Roughened with Single Discrete Arc-Shaped Ribs
Raj Kumar (Autor:in) / Erdem Cuce (Autor:in) / Sushil Kumar (Autor:in) / Sashank Thapa (Autor:in) / Paras Gupta (Autor:in) / Bhaskar Goel (Autor:in) / C. Ahamed Saleel (Autor:in) / Saboor Shaik (Autor:in)
2022
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
British Library Online Contents | 2019
|Optimization of thermo hydraulic performance in three sides artificially roughened solar air heaters
British Library Online Contents | 2015
|American Institute of Physics | 2012
|