Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation Study
The paper considers the issue of the thermal refurbishment of residential buildings built between 10 and 40 years ago in some European countries. It suggests that, while facade retrofitting is the most effective solution for older dwellings, all actions are equally less effective for newer dwellings built in this millennium. According to the current situation, as society shifts away from the use of fossil fuels, this paper presents the expected energy and financial savings that were calculated using one of four different heating sources. The study shows that the efficiency of the additional thermal retrofitting of the structures is low when the building is heated with a heat pump. The addition of thermal insulation to already well-insulated roofs or floors results in minimal savings of approximately 0.15 kWh per square meter of heated floor area per year. The potential advantage of replacing existing windows with new windows in a top thermal quality was shown. After window replacement, the financial benefits could be twice as high in houses heated by district heating compared to houses heated by gas or a heat pump, including an alternative heat pump with photovoltaics.
Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation Study
The paper considers the issue of the thermal refurbishment of residential buildings built between 10 and 40 years ago in some European countries. It suggests that, while facade retrofitting is the most effective solution for older dwellings, all actions are equally less effective for newer dwellings built in this millennium. According to the current situation, as society shifts away from the use of fossil fuels, this paper presents the expected energy and financial savings that were calculated using one of four different heating sources. The study shows that the efficiency of the additional thermal retrofitting of the structures is low when the building is heated with a heat pump. The addition of thermal insulation to already well-insulated roofs or floors results in minimal savings of approximately 0.15 kWh per square meter of heated floor area per year. The potential advantage of replacing existing windows with new windows in a top thermal quality was shown. After window replacement, the financial benefits could be twice as high in houses heated by district heating compared to houses heated by gas or a heat pump, including an alternative heat pump with photovoltaics.
Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation Study
Radoslav Ponechal (Autor:in) / Jozef Jandačka (Autor:in) / Pavol Ďurica (Autor:in)
2024
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Climate Zone-Based Energy Retrofits—Residential Buildings in Canada
Springer Verlag | 2023
|British Library Conference Proceedings | 2019
|Lighting retrofits power Minneapolis energy savings
British Library Online Contents | 2018