Effect of drainage and insulating joint methods for prevention of electrolytic corrosion of underground metallic structures
Effect of two methods for prevention of electrolytic corrosion of underground metallic structures, using either drainage connection or insulating joint for power and communication cables, from data obtained by laboratory experiment and field survey.
Effect of drainage and insulating joint methods for prevention of electrolytic corrosion of underground metallic structures
Effect of two methods for prevention of electrolytic corrosion of underground metallic structures, using either drainage connection or insulating joint for power and communication cables, from data obtained by laboratory experiment and field survey.
Effect of drainage and insulating joint methods for prevention of electrolytic corrosion of underground metallic structures
Electrotech. Laboratory -- Researches
Horioka, M. (Autor:in) / Iwasa, M. (Autor:in)
1930
82 pages
Numerous figs., Partly on supp. plates
Aufsatz (Zeitschrift)
Japanisch
© Metadata Copyright Elsevier B. V. All rights reserved.
Engineering Index Backfile | 1931
|Underground corrosion of metallic structures
Engineering Index Backfile | 1941
|Engineering Index Backfile | 1912
|Corrosion Control for Underground Metallic Structures