Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Failure of concrete compression test specimens
Tests on number of compression specimens have shown that failure is frequently due to splitting of specimen into two or more parts; splitting is believed to be due to induced lateral tensile strain; mathematical expression is derived for strains.
Failure of concrete compression test specimens
Tests on number of compression specimens have shown that failure is frequently due to splitting of specimen into two or more parts; splitting is believed to be due to induced lateral tensile strain; mathematical expression is derived for strains.
Failure of concrete compression test specimens
Civ Eng (Lond)
Neville, A.M. (Autor:in)
Civil Engineering ; 52
1957
2 pages
Aufsatz (Zeitschrift)
Englisch
© Metadata Copyright Elsevier B. V. All rights reserved.
Mechanics of failure of standard concrete test specimens
Engineering Index Backfile | 1932
|Capping of concrete test specimens
Engineering Index Backfile | 1945
|Engineering Index Backfile | 1964
|