Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Structural problems -- New boiler house, Yallourn
Construction of No. 2 boiler house at station of State Electricity Commission of Victoria; foundations, fixing columns to concrete bases by bond; compression bond tests; supporting chimney loads; elimination of vibrations in girders, connecting coal-bunker structure to main columns, involving unusual shear stress problems; derivation of column formula.
Structural problems -- New boiler house, Yallourn
Construction of No. 2 boiler house at station of State Electricity Commission of Victoria; foundations, fixing columns to concrete bases by bond; compression bond tests; supporting chimney loads; elimination of vibrations in girders, connecting coal-bunker structure to main columns, involving unusual shear stress problems; derivation of column formula.
Structural problems -- New boiler house, Yallourn
Instn Engrs Australia -- J
Saunders, E. (Autor:in)
1932
11 pages
Aufsatz (Zeitschrift)
Englisch
© Metadata Copyright Elsevier B. V. All rights reserved.
Design of reinforced concrete chimney at Yallourn briquetting works
Engineering Index Backfile | 1924
|Satisfaction and Positive Resettlement: Evidence From Yallourn, Latrobe Valley, Australia
Taylor & Francis Verlag | 1980
|Yallourn Open Cut Mine East Field Overburden Dewatering and Southern Dump Stability Analysis
British Library Conference Proceedings | 1999
|Engineering Index Backfile | 1925
Engineering Index Backfile | 1905
|