Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Strength of longitudinally stiffened plate girders
Methods of estimating bending strength and shear strength of longitudinally stiffened plate girders are described and compared with test results; it is concluded that substantial increase in static strength of plate girders can result from use of longitudinal stiffeners.
Strength of longitudinally stiffened plate girders
Methods of estimating bending strength and shear strength of longitudinally stiffened plate girders are described and compared with test results; it is concluded that substantial increase in static strength of plate girders can result from use of longitudinal stiffeners.
Strength of longitudinally stiffened plate girders
ASCE -- Proc (J Structural Div)
Cooper, P.B. (Autor:in)
1967
33 pages
Aufsatz (Zeitschrift)
Englisch
© Metadata Copyright Elsevier B. V. All rights reserved.
Patch loading resistance of longitudinally stiffened plate girders
Tema Archiv | 2006
|Shear capacity of longitudinally stiffened girders
British Library Conference Proceedings | 2004
|Longitudinally stiffened hybrid steel plate girders subjected to patch loading
Online Contents | 2011
|