Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Corrosion of structural steel and steel reinforcing rods encased in concrete
Description of corrosion which occurred in both structural steel and reinforced concrete in engine-room floor of department store in Toronto; conclusions were that corrosion had been caused: by cracks in concrete slab, due to omission of reinforcing rods in top of slab; presence of water and brine solution on top of slab finding its way through these cracks; excessive condensation on underside of slab at openings in floors combined with high temperature.
Corrosion of structural steel and steel reinforcing rods encased in concrete
Description of corrosion which occurred in both structural steel and reinforced concrete in engine-room floor of department store in Toronto; conclusions were that corrosion had been caused: by cracks in concrete slab, due to omission of reinforcing rods in top of slab; presence of water and brine solution on top of slab finding its way through these cracks; excessive condensation on underside of slab at openings in floors combined with high temperature.
Corrosion of structural steel and steel reinforcing rods encased in concrete
Engineering
Cross, E.A. (Autor:in)
Engineering ; 130
1930
6 Figs.
Aufsatz (Zeitschrift)
Englisch
© Metadata Copyright Elsevier B. V. All rights reserved.
Special-shaped steel-encased-concrete composite beam reinforcing structure
Europäisches Patentamt | 2024
|Steel-encased-ultra-high-performance concrete reinforcing method for box girder
Europäisches Patentamt | 2021
|Steel reinforcing bars and steel spiral rods
Engineering Index Backfile | 1931
|Concrete-encased steel pier at deal
Engineering Index Backfile | 1957