Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
British standard permits concrete casing of encased steel stanchions to be assumed to contribute to load carrying capacity of stanchion; tests at Building Research Station, on stanchions subjected to axial or eccentric compression, justifying design rules of new standard; tables show test results.
British standard permits concrete casing of encased steel stanchions to be assumed to contribute to load carrying capacity of stanchion; tests at Building Research Station, on stanchions subjected to axial or eccentric compression, justifying design rules of new standard; tables show test results.
Encased steel stanchions and BS 449
Engineering
Stevens, R.F. (Autor:in)
Engineering ; 188
1959
2 pages
Aufsatz (Zeitschrift)
Englisch
© Metadata Copyright Elsevier B. V. All rights reserved.
Engineering Index Backfile | 1965
|Strength of encased steel stanchions
Engineering Index Backfile | 1955
|Fire resistance of encased steel stanchions
Engineering Index Backfile | 1964
|Fire resistance of encased steel stanchions
Engineering Index Backfile | 1964
|The strength of encased stanchions
TIBKAT | 1965
|