On the heat transfer coefficients between heated/cooled radiant floor and room
Graphical abstract
Highlights Experimental research on heated/cooled radiant floor in the climatic chamber. Overestimation of heat flux using literature value of heat transfer coefficient. New values of radiant, convective and total heat transfer coefficients. Coefficients required in dimensioning or scientific analyzes of radiant floor.
Abstract The radiant floor heating/cooling systems are more often used in new designed and modernized buildings, what renewed the interest in the study of the characteristic parameters, which are taking in to account by dimensioning or detailed scientific analyzes of such a systems. Very important and fundamental characteristic parameters for radiant floor are heat transfer coefficients. This article presents the results of experimental research on heated/cooled radiant floor conducted in the laboratory room in the climatic chamber, which aim was to estimate experimentally the values of heat transfer coefficients for the surface of cooled/heated radiant floor. The values of radiant, convective and total heat transfer coefficients were developed on the basis of the amount of heat emitted from the radiant surface and by the use of proper and clearly defined reference temperature depending on the kind of heat transfer coefficient. It was noticed, that the values of heat transfer coefficients for heated/cooled radiant floor, which are commonly used in practice, are overestimated, even in the range of 10–30%.
On the heat transfer coefficients between heated/cooled radiant floor and room
Graphical abstract
Highlights Experimental research on heated/cooled radiant floor in the climatic chamber. Overestimation of heat flux using literature value of heat transfer coefficient. New values of radiant, convective and total heat transfer coefficients. Coefficients required in dimensioning or scientific analyzes of radiant floor.
Abstract The radiant floor heating/cooling systems are more often used in new designed and modernized buildings, what renewed the interest in the study of the characteristic parameters, which are taking in to account by dimensioning or detailed scientific analyzes of such a systems. Very important and fundamental characteristic parameters for radiant floor are heat transfer coefficients. This article presents the results of experimental research on heated/cooled radiant floor conducted in the laboratory room in the climatic chamber, which aim was to estimate experimentally the values of heat transfer coefficients for the surface of cooled/heated radiant floor. The values of radiant, convective and total heat transfer coefficients were developed on the basis of the amount of heat emitted from the radiant surface and by the use of proper and clearly defined reference temperature depending on the kind of heat transfer coefficient. It was noticed, that the values of heat transfer coefficients for heated/cooled radiant floor, which are commonly used in practice, are overestimated, even in the range of 10–30%.
On the heat transfer coefficients between heated/cooled radiant floor and room
Cholewa, Tomasz (Autor:in) / Rosiński, Marian (Autor:in) / Spik, Zenon (Autor:in) / Dudzińska, Marzenna R. (Autor:in) / Siuta-Olcha, Alicja (Autor:in)
Energy and Buildings ; 66 ; 599-606
25.07.2013
8 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
On the heat transfer coefficients between heated/cooled radiant floor and room
Online Contents | 2013
|Experimental evaluation of heat transfer coefficients between radiant ceiling and room
Online Contents | 2009
|