Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Robustness of large-span timber roof structures — Two examples
Abstract This paper discusses the robustness of large-span timber roof structures, based on findings from failures of two roof structures. One is the Siemens arena in Ballerup, Denmark and the other the Bad Reichenhall ice-arena in Germany. The structures are described as well as the flaws that are believed to have caused the failures. The two cases serve as examples of different design strategies for large-span timber roof structures and the consequences of such strategies for robustness. It is demonstrated that robustness is not a straightforward concept because the best strategy depends on the cause of the failure — which is obviously not known during planning and design.
Robustness of large-span timber roof structures — Two examples
Abstract This paper discusses the robustness of large-span timber roof structures, based on findings from failures of two roof structures. One is the Siemens arena in Ballerup, Denmark and the other the Bad Reichenhall ice-arena in Germany. The structures are described as well as the flaws that are believed to have caused the failures. The two cases serve as examples of different design strategies for large-span timber roof structures and the consequences of such strategies for robustness. It is demonstrated that robustness is not a straightforward concept because the best strategy depends on the cause of the failure — which is obviously not known during planning and design.
Robustness of large-span timber roof structures — Two examples
Munch-Andersen, Jørgen (Autor:in) / Dietsch, Philipp (Autor:in)
Engineering Structures ; 33 ; 3113-3117
01.01.2011
5 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Timber , Structure , Large span roof , Failure , Robustness , Redundancy , Indeterminacy
Robustness of large-span timber roof structures — Two examples
Online Contents | 2011
|Robustness of large-span timber roof structures — Structural aspects
Elsevier | 2011
|Robustness of large-span timber roof structures — Structural aspects
Online Contents | 2011
|