Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Application characteristics of variable refrigerant flow heat pump system with vapor injection in severe cold region
Abstract Variable refrigerant flow heat pump system is still restricted in use in severe cold region due to ultra-low outdoor temperature there. With the development of vapor injection technique, applying this technique to it is an effective method to promote its heating performance at low outdoor temperature. To promote the application of variable refrigerant flow heat pump system with vapor injection in severe cold region, a test rig was built in Harbin and used to supply heating for a lab. To prevent excessive discharge temperature at ultra-low outdoor temperature, a novel control strategy was proposed and used in the test rig. The application characteristics of the experimental unit were introduced firstly. Then its application potential was analyzed through comparing with quasi-two stage compression air-water heat pump. Results showed the experimental unit run smoothly in the whole test period, even when outdoor temperature dropped to −28.7 °C. Its heating effect was good at outdoor temperature of −22.5 to 7.5 °C. Besides, mal-defrost had more serious influence on heating capacity shortage than ultra-low outdoor temperature in severe cold region. In addition, comparing with quasi-two stage compression air-water heat pump, the experimental unit had advantage on heating capacity and discharge temperature.
Application characteristics of variable refrigerant flow heat pump system with vapor injection in severe cold region
Abstract Variable refrigerant flow heat pump system is still restricted in use in severe cold region due to ultra-low outdoor temperature there. With the development of vapor injection technique, applying this technique to it is an effective method to promote its heating performance at low outdoor temperature. To promote the application of variable refrigerant flow heat pump system with vapor injection in severe cold region, a test rig was built in Harbin and used to supply heating for a lab. To prevent excessive discharge temperature at ultra-low outdoor temperature, a novel control strategy was proposed and used in the test rig. The application characteristics of the experimental unit were introduced firstly. Then its application potential was analyzed through comparing with quasi-two stage compression air-water heat pump. Results showed the experimental unit run smoothly in the whole test period, even when outdoor temperature dropped to −28.7 °C. Its heating effect was good at outdoor temperature of −22.5 to 7.5 °C. Besides, mal-defrost had more serious influence on heating capacity shortage than ultra-low outdoor temperature in severe cold region. In addition, comparing with quasi-two stage compression air-water heat pump, the experimental unit had advantage on heating capacity and discharge temperature.
Application characteristics of variable refrigerant flow heat pump system with vapor injection in severe cold region
Wei, Wenzhe (Autor:in) / Ni, Long (Autor:in) / Xu, Laifu (Autor:in) / Yang, Yahua (Autor:in) / Yao, Yang (Autor:in)
Energy and Buildings ; 211
17.01.2020
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Variable Refrigerant Flow: An Emerging Air Conditioner and Heat Pump Technology
British Library Conference Proceedings | 2008
|Development of variable refrigerant flow heat-pump model for annual-energy simulation
Taylor & Francis Verlag | 2021
|DA-13-026 A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus
British Library Conference Proceedings | 2013
|DA-13-026 A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus
British Library Online Contents | 2013
|