Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Behavior of FRP-confined concrete after high temperature exposure
Abstract This paper presents the results of an experimental program to investigate the effect of high temperature on the performance of concrete externally confined with FRP sheets. For this purpose, a two-phase experimental program was conducted. In the first phase, 42 standard 100×200mm concrete cylinders were prepared. Out of these specimens, 14 cylinders were left unwrapped; 14 specimens were wrapped with one layer of CFRP sheet; and the remaining 14 specimens were wrapped with one layer of GFRP sheet. Some of the unconfined and FRP-confined specimens were exposed to room temperature; whereas, other cylinders were exposed to heating regime of 100°C and 200°C for a period of 1, 2 or 3h. After high temperature exposure, specimens were tested under uniaxial compression till failure. The test results demonstrated that at a temperature of 100°C (a little more than the glass transition temperature (Tg) of the epoxy resin), both CFRP- and GFRP-wrapped specimens experienced small loss in strength resulting from melting of epoxy. This loss of strength was more pronounced when the temperature reached 200°C. In the second phase of the experimental program, three 100×100×650mm concrete prisms were prepared and then overlaid by one layer of CFRP and GFRP laminates for conducting pull-off strength tests as per ASTM D4541 – 09. The objective of this testing was to evaluate the degradation in bond strength between FRP and concrete substrate when exposed to elevated temperature environments. One prism was exposed to room temperature whereas the other two specimens were exposed to heating regime of 100°C and 200°C for a period of 3h. It was concluded that a significant degradation in the bond strength occurred at a temperature of 200°C especially for CFRP-overlaid specimens.
Behavior of FRP-confined concrete after high temperature exposure
Abstract This paper presents the results of an experimental program to investigate the effect of high temperature on the performance of concrete externally confined with FRP sheets. For this purpose, a two-phase experimental program was conducted. In the first phase, 42 standard 100×200mm concrete cylinders were prepared. Out of these specimens, 14 cylinders were left unwrapped; 14 specimens were wrapped with one layer of CFRP sheet; and the remaining 14 specimens were wrapped with one layer of GFRP sheet. Some of the unconfined and FRP-confined specimens were exposed to room temperature; whereas, other cylinders were exposed to heating regime of 100°C and 200°C for a period of 1, 2 or 3h. After high temperature exposure, specimens were tested under uniaxial compression till failure. The test results demonstrated that at a temperature of 100°C (a little more than the glass transition temperature (Tg) of the epoxy resin), both CFRP- and GFRP-wrapped specimens experienced small loss in strength resulting from melting of epoxy. This loss of strength was more pronounced when the temperature reached 200°C. In the second phase of the experimental program, three 100×100×650mm concrete prisms were prepared and then overlaid by one layer of CFRP and GFRP laminates for conducting pull-off strength tests as per ASTM D4541 – 09. The objective of this testing was to evaluate the degradation in bond strength between FRP and concrete substrate when exposed to elevated temperature environments. One prism was exposed to room temperature whereas the other two specimens were exposed to heating regime of 100°C and 200°C for a period of 3h. It was concluded that a significant degradation in the bond strength occurred at a temperature of 200°C especially for CFRP-overlaid specimens.
Behavior of FRP-confined concrete after high temperature exposure
Al-Salloum, Yousef A. (Autor:in) / Elsanadedy, Hussein M. (Autor:in) / Abadel, Aref A. (Autor:in)
Construction and Building Materials ; 25 ; 838-850
29.06.2010
13 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Behavior of FRP-confined concrete after high temperature exposure
Online Contents | 2011
|Behavior of FRP-confined concrete after high temperature exposure
British Library Online Contents | 2011
|An empirical model for confined concrete after exposure to high temperature
British Library Online Contents | 2017
|An empirical model for confined concrete after exposure to high temperature
Online Contents | 2017
|