Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Upgrading the seismic performance of underground structures by introducing lead-filled steel tube dampers
Highlights Lead-filled steel tube dampers can improve seismic performance of underground structures. We compare 3D nonlinear dynamic structural analyses with and without the LFSTDs. LFSTDs lower deformation of and damage to the central column under seismic loading. The LFSTD functions best at a strength ratio of 0.4. Arrangement modes of the LFSTDs are compared in application of underground structures.
Abstract Central-column failure can cause large underground structures to collapse during strong earthquakes. The use of lead-filled steel-tube dampers (LFSTDs) in the seismic design of such structures is proposed to mitigate or prevent such an eventuality. Three-dimensional nonlinear dynamic analyses of the Daikai subway station with and without LFSTDs under the action of the Hyogoken–Nambu earthquake has been performed, considering soil-structure interaction. The feasibility of the proposed method was verified from four aspects—force, deformation, damage, and energy dissipation. The effects of variability in seismic inputs, strength ratio, and arrangement mode of dampers on the structural dynamic response characteristics have been discussed. Results reveal that the application of LFSTDs to large underground structures remarkably reduces the force, deformation, and damage associated with the central column under seismic loading. Additionally, a strength ratio of 0.4 is recommended when using LFSTDs, whereas in cases without LFTSTDs, the strength of the central column must be appropriately enhanced.
Upgrading the seismic performance of underground structures by introducing lead-filled steel tube dampers
Highlights Lead-filled steel tube dampers can improve seismic performance of underground structures. We compare 3D nonlinear dynamic structural analyses with and without the LFSTDs. LFSTDs lower deformation of and damage to the central column under seismic loading. The LFSTD functions best at a strength ratio of 0.4. Arrangement modes of the LFSTDs are compared in application of underground structures.
Abstract Central-column failure can cause large underground structures to collapse during strong earthquakes. The use of lead-filled steel-tube dampers (LFSTDs) in the seismic design of such structures is proposed to mitigate or prevent such an eventuality. Three-dimensional nonlinear dynamic analyses of the Daikai subway station with and without LFSTDs under the action of the Hyogoken–Nambu earthquake has been performed, considering soil-structure interaction. The feasibility of the proposed method was verified from four aspects—force, deformation, damage, and energy dissipation. The effects of variability in seismic inputs, strength ratio, and arrangement mode of dampers on the structural dynamic response characteristics have been discussed. Results reveal that the application of LFSTDs to large underground structures remarkably reduces the force, deformation, and damage associated with the central column under seismic loading. Additionally, a strength ratio of 0.4 is recommended when using LFSTDs, whereas in cases without LFTSTDs, the strength of the central column must be appropriately enhanced.
Upgrading the seismic performance of underground structures by introducing lead-filled steel tube dampers
He, Zhiming (Autor:in) / Chen, Qingjun (Autor:in)
12.11.2020
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Seismic Performance Upgrading for Underground Structures by Introducing Shear Panel Dampers
SAGE Publications | 2014
|Seismic Performance Upgrading for Underground Structures by Introducing Shear Panel Dampers
Online Contents | 2014
|Seismic performance upgrading for underground structures by introducing sliding isolation bearings
British Library Online Contents | 2018
|Seismic performance of steel structures with slit dampers
Elsevier | 2009
|Seismic performance of steel structures with slit dampers
Online Contents | 2009
|