An interpolatory basis lumped mass isogeometric formulation with rigorous assessment of frequency accuracy for Kirchhoff plates
Highlights An interpolatory basis lumped mass isogeometric formulation is proposed for accurate frequency computation of Kirchhoff plates. Nodal quadrature rules are developed to formulate isogeometric lumped mass matrices with interpolatory basis functions. A frequency equivalence is rationally established between different isogeometric mass matrix formulations. Rigorous theoretical frequency error estimates are presented for the lumped mass isogeometric formulation with interpolatory basis functions. The 4th and 6th order accuracy of the proposed method with cubic and quartic basis functions contrasts sharply to the 2nd order accuracy of standard approach.
Abstract A noticeable drawback associated with the isogeometric free vibration analysis of Kirchhoff plates with lumped mass formulation is that its frequency accuracy is strongly limited to 2nd order, no matter what degrees of basis functions are used. This issue is resolved herein by a lumped mass isogeometric formulation using a set of interpolatory basis functions. These interpolatory basis functions are constructed via transforming the standard isogeometric basis functions with respect to the Greville nodes. A direct consequence of the basis interpolation property is that the resulting lumped mass matrices can be realized with a nodal integration technique, and the corresponding nodal quadrature rules are then developed for cubic and quartic basis functions. Furthermore, based upon the transformation relationship between the standard and interpolatory basis functions, a frequency equivalence is rationally established between the standard and transformed isogeometric formulations, which enables a rigorous analytical study of the frequency accuracy for the proposed approach. In particular, the theoretical frequency error estimates are obtained for both cubic and quartic basis functions, which clearly illustrate the frequency accuracy superiority of the proposed method over the standard lumped mass isogeometric formulation for Kirchhoff plates. The theoretical observations are simultaneously demonstrated by numerical results.
An interpolatory basis lumped mass isogeometric formulation with rigorous assessment of frequency accuracy for Kirchhoff plates
Highlights An interpolatory basis lumped mass isogeometric formulation is proposed for accurate frequency computation of Kirchhoff plates. Nodal quadrature rules are developed to formulate isogeometric lumped mass matrices with interpolatory basis functions. A frequency equivalence is rationally established between different isogeometric mass matrix formulations. Rigorous theoretical frequency error estimates are presented for the lumped mass isogeometric formulation with interpolatory basis functions. The 4th and 6th order accuracy of the proposed method with cubic and quartic basis functions contrasts sharply to the 2nd order accuracy of standard approach.
Abstract A noticeable drawback associated with the isogeometric free vibration analysis of Kirchhoff plates with lumped mass formulation is that its frequency accuracy is strongly limited to 2nd order, no matter what degrees of basis functions are used. This issue is resolved herein by a lumped mass isogeometric formulation using a set of interpolatory basis functions. These interpolatory basis functions are constructed via transforming the standard isogeometric basis functions with respect to the Greville nodes. A direct consequence of the basis interpolation property is that the resulting lumped mass matrices can be realized with a nodal integration technique, and the corresponding nodal quadrature rules are then developed for cubic and quartic basis functions. Furthermore, based upon the transformation relationship between the standard and interpolatory basis functions, a frequency equivalence is rationally established between the standard and transformed isogeometric formulations, which enables a rigorous analytical study of the frequency accuracy for the proposed approach. In particular, the theoretical frequency error estimates are obtained for both cubic and quartic basis functions, which clearly illustrate the frequency accuracy superiority of the proposed method over the standard lumped mass isogeometric formulation for Kirchhoff plates. The theoretical observations are simultaneously demonstrated by numerical results.
An interpolatory basis lumped mass isogeometric formulation with rigorous assessment of frequency accuracy for Kirchhoff plates
Li, Xiwei (Autor:in) / Hou, Songyang (Autor:in) / Wang, Dongdong (Autor:in)
Thin-Walled Structures ; 197
25.01.2024
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Isogeometric-Meshfree Coupled Analysis of Kirchhoff Plates
SAGE Publications | 2014
|Frequency Analysis of Variable Thickness Kirchhoff Plates by Isogeometric Approach
Springer Verlag | 2023
|Isogeometric-Meshfree Coupled Analysis of Kirchhoff Plates
Online Contents | 2014
|Isogeometric-Meshfree Coupled Analysis of Kirchhoff Plates
British Library Conference Proceedings | 2014
|A frequency error estimation for isogeometric analysis of Kirchhoff–Love cylindrical shells
Springer Verlag | 2023
|