Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Nicotine, RSP, and CO2 levels in bars and nightclubs
AbstractVapor phase nicotine and respirable suspended particle (RSP) concentrations were measured in bars and nightclubs as indicators of exposure to environmental tobacco smoke (ETS). The CO2 concentrations were continuously monitored to provide a gross indication of ventilation adequacy, and occupant activities were observed. Results showed higher nicotine and RSP concentrations than have been reported for other indoor environments. Levels of ETS-related constituents varied widely between different nightclubs, taverns, and neighborhood pubs, depending on type of establishment, occupancy levels, amount of smoking, and ventilation adequacy. Mean nicotine concentrations were 58 μg/m3, 46.6 μg/m3, and 38.6 μg/m3 for nightclubs, taverns and neighborhood pubs, respectively. Mean RSP concentrations were 151 μg/m3, 93 μg/m3, and 95 μg/m3. The higher ETS-related concentrations were associated with elevated CO2 levels, the highest occupancy levels, and cigarette consumption. In all establishments, CO2 concentrations exceeded the 1 mL/L criterion for acceptable indoor air quality used in ASHRAE Standard 62–1989.
Nicotine, RSP, and CO2 levels in bars and nightclubs
AbstractVapor phase nicotine and respirable suspended particle (RSP) concentrations were measured in bars and nightclubs as indicators of exposure to environmental tobacco smoke (ETS). The CO2 concentrations were continuously monitored to provide a gross indication of ventilation adequacy, and occupant activities were observed. Results showed higher nicotine and RSP concentrations than have been reported for other indoor environments. Levels of ETS-related constituents varied widely between different nightclubs, taverns, and neighborhood pubs, depending on type of establishment, occupancy levels, amount of smoking, and ventilation adequacy. Mean nicotine concentrations were 58 μg/m3, 46.6 μg/m3, and 38.6 μg/m3 for nightclubs, taverns and neighborhood pubs, respectively. Mean RSP concentrations were 151 μg/m3, 93 μg/m3, and 95 μg/m3. The higher ETS-related concentrations were associated with elevated CO2 levels, the highest occupancy levels, and cigarette consumption. In all establishments, CO2 concentrations exceeded the 1 mL/L criterion for acceptable indoor air quality used in ASHRAE Standard 62–1989.
Nicotine, RSP, and CO2 levels in bars and nightclubs
Collett, Chris W. (Autor:in) / Ross, James A. (Autor:in) / Levine, Karen B. (Autor:in)
Environmental International ; 18 ; 347-352
24.03.1992
6 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Space Racy: A new Sydney designer's Copenhagen nightclubs
British Library Online Contents | 1998
Space Racy - A new Sydney designer's Copenhagen nightclubs
Online Contents | 1998
The Pleasure of Public Space Muhammad `Ali Street and the Nightclubs in Cairo (1900-1950)
British Library Conference Proceedings | 2001
|The Station tragedy has led to new recommendations to improve safety in nightclubs
British Library Online Contents | 2005