Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Performance evaluation of three attached ventilation scenarios for tiny sleeping spaces
Abstract The indoor ventilation environment has restricted the development of tiny sleeping spaces, such as capsule hotels, sleeping boxes and soft sleeper compartments, that play an increasingly important role in urban life. Thus, it is imperative to determine a ventilation method that can create comfortable sleeping environments in tiny spaces. In this study, three attached ventilation scenarios were proposed, and numerical simulations and experimental validations were conducted to investigate the airflow characteristics. The draught rate, facial-area speed ratio, predicted mean vote, CO2 concentration, ventilation effectiveness, and mean age of air were used to evaluate the performance of three ventilation scenarios. In Scenario 1, the velocity in the occupied zone was between 0.1 and 0.24 m/s, which could achieve the most comfortable facial speed distribution; the PMV also met the criteria for category B (−0.5 < PMV < +0.5), as defined in ISO 7730. Scenario 2 had a more uniform temperature distribution and minimum air age; however, the local velocity was too high (more than 0.5 m/s), and CO2 cannot be discharged from the occupied zone in time. The DR in Scenario 3 was in the range of 2.5%–5.3%, which was highly beneficial in avoiding draught. Finally, the overall performance of the three ventilation scenarios was as follows: Scenario 1 was superior to Scenario 3, which in turn, was superior to Scenario 2. The results showed that the attached ventilation could solve the problem of supply air momentum not being able to diffuse in a reasonable time in restricted spaces.
Highlights Three attached ventilation scenarios were proposed for tiny sleeping space. Air distribution, thermal comfort and air quality of tiny sleeping space were studied. Multiple indicators evaluated the overall performance of three ventilation scenarios. Attached ventilation can avoid the draught in tiny space (occupied zone DR less than 20%). Double-side-attached ventilation has the best performance for confined spaces.
Performance evaluation of three attached ventilation scenarios for tiny sleeping spaces
Abstract The indoor ventilation environment has restricted the development of tiny sleeping spaces, such as capsule hotels, sleeping boxes and soft sleeper compartments, that play an increasingly important role in urban life. Thus, it is imperative to determine a ventilation method that can create comfortable sleeping environments in tiny spaces. In this study, three attached ventilation scenarios were proposed, and numerical simulations and experimental validations were conducted to investigate the airflow characteristics. The draught rate, facial-area speed ratio, predicted mean vote, CO2 concentration, ventilation effectiveness, and mean age of air were used to evaluate the performance of three ventilation scenarios. In Scenario 1, the velocity in the occupied zone was between 0.1 and 0.24 m/s, which could achieve the most comfortable facial speed distribution; the PMV also met the criteria for category B (−0.5 < PMV < +0.5), as defined in ISO 7730. Scenario 2 had a more uniform temperature distribution and minimum air age; however, the local velocity was too high (more than 0.5 m/s), and CO2 cannot be discharged from the occupied zone in time. The DR in Scenario 3 was in the range of 2.5%–5.3%, which was highly beneficial in avoiding draught. Finally, the overall performance of the three ventilation scenarios was as follows: Scenario 1 was superior to Scenario 3, which in turn, was superior to Scenario 2. The results showed that the attached ventilation could solve the problem of supply air momentum not being able to diffuse in a reasonable time in restricted spaces.
Highlights Three attached ventilation scenarios were proposed for tiny sleeping space. Air distribution, thermal comfort and air quality of tiny sleeping space were studied. Multiple indicators evaluated the overall performance of three ventilation scenarios. Attached ventilation can avoid the draught in tiny space (occupied zone DR less than 20%). Double-side-attached ventilation has the best performance for confined spaces.
Performance evaluation of three attached ventilation scenarios for tiny sleeping spaces
Yin, Haiguo (Autor:in) / Li, Yanyan (Autor:in) / Deng, Xin (Autor:in) / Han, Yuekun (Autor:in) / Wang, Lijuan (Autor:in) / Yang, Bin (Autor:in) / Li, Angui (Autor:in)
Building and Environment ; 186
05.10.2020
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Airflow pattern and performance of attached ventilation for two types of tiny spaces
Springer Verlag | 2022
|Experimental study on the CO2 concentration and age of air distribution inside tiny sleeping spaces
Springer Verlag | 2024
|Experimental study on the CO2 concentration and age of air distribution inside tiny sleeping spaces
Springer Verlag | 2024
|Ventilation of steel sleeping cars
Engineering Index Backfile | 1913
|Evaluation of ventilation performance in public spaces
British Library Conference Proceedings | 1998
|