Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Behaviour of grouted pipe splice under incremental tensile load
Highlights ► Grouted splice is utilized to confine of high strength grout for splicing of steel bars. ► Confinement is quantified from peripheral tensile strain of sleeve. ► Behaviour of the sleeve can be acquired from experimental results.
Abstract This paper presents the behaviour and performance of grouted splice connection. A sleeve is utilized to confine the splicing of two discontinued bars, and as a result, the bond performance between the bars and the bonding material can be improved. Two new sleeves, fabricated from standard size steel pipes, were proposed and the grouted splice specimens were tested under incremental tensile load until failure of the specimens, either by bar bond-slip or bar fracture failure. The behaviour of the specimens, which is represented by the load–displacement response, is discussed, and it is found that the geometrical configurations of the sleeve provide significant influence to the bond performance due to the effects of confinement generated by the sleeve.
Behaviour of grouted pipe splice under incremental tensile load
Highlights ► Grouted splice is utilized to confine of high strength grout for splicing of steel bars. ► Confinement is quantified from peripheral tensile strain of sleeve. ► Behaviour of the sleeve can be acquired from experimental results.
Abstract This paper presents the behaviour and performance of grouted splice connection. A sleeve is utilized to confine the splicing of two discontinued bars, and as a result, the bond performance between the bars and the bonding material can be improved. Two new sleeves, fabricated from standard size steel pipes, were proposed and the grouted splice specimens were tested under incremental tensile load until failure of the specimens, either by bar bond-slip or bar fracture failure. The behaviour of the specimens, which is represented by the load–displacement response, is discussed, and it is found that the geometrical configurations of the sleeve provide significant influence to the bond performance due to the effects of confinement generated by the sleeve.
Behaviour of grouted pipe splice under incremental tensile load
Ling, Jen Hua (Autor:in) / Abd. Rahman, Ahmad Baharuddin (Autor:in) / Ibrahim, Izni Syahrizal (Autor:in) / Abdul Hamid, Zuhairi (Autor:in)
Construction and Building Materials ; 33 ; 90-98
01.02.2012
9 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Behaviour of grouted pipe splice under incremental tensile load
British Library Online Contents | 2012
|Behaviour of grouted pipe splice under incremental tensile load
Online Contents | 2012
|Performance and confining mechanism of grouted deformed pipe splice under tensile load
SAGE Publications | 2016
|Feasibility study of grouted splice connector under tensile load
British Library Online Contents | 2014
|