Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Cyclic testing of steel beam blind bolted to CFST column composite frames with SBTD concrete slabs
HighlightsCyclic test of two blind bolted CFST frames with SBTD concrete slabs was conducted.Effect of column section and endplate type on seismic behavior of frames was studied.Crack pattern of SBTD concrete slab in CFST composite frames were analyzed.
AbstractThis paper aims to investigate the seismic behavior and failure mechanism of novel type of blind bolted concrete-filled steel tubular (CFST) composite frames under seismic loading. The composite frames are composed of square or circular CFST columns and steel-concrete composite beams with steel-bars truss deck (SBTD); the steel beams and the CFST columns are assembled by blind bolts and end plates. The failure modes, hysteretic behavior, strength and rigidity degradation, ductility and energy-dissipating performance of all specimens were analyzed and discussed. The influence of composite action of the floor slab on the performance of blind bolted CFST composite frames were also explored under seismic loading. The experimental results showed that the blind bolted CFST composite frames with the SBTD concrete slabs exhibited good hysteretic behavior, large ductility and high energy dissipation. The stiffness and strength of the frame increased greatly with the presence of the SBTD concrete slab. These test studies could promote the engineering design and application of the blind bolted CFST composite frames.
Cyclic testing of steel beam blind bolted to CFST column composite frames with SBTD concrete slabs
HighlightsCyclic test of two blind bolted CFST frames with SBTD concrete slabs was conducted.Effect of column section and endplate type on seismic behavior of frames was studied.Crack pattern of SBTD concrete slab in CFST composite frames were analyzed.
AbstractThis paper aims to investigate the seismic behavior and failure mechanism of novel type of blind bolted concrete-filled steel tubular (CFST) composite frames under seismic loading. The composite frames are composed of square or circular CFST columns and steel-concrete composite beams with steel-bars truss deck (SBTD); the steel beams and the CFST columns are assembled by blind bolts and end plates. The failure modes, hysteretic behavior, strength and rigidity degradation, ductility and energy-dissipating performance of all specimens were analyzed and discussed. The influence of composite action of the floor slab on the performance of blind bolted CFST composite frames were also explored under seismic loading. The experimental results showed that the blind bolted CFST composite frames with the SBTD concrete slabs exhibited good hysteretic behavior, large ductility and high energy dissipation. The stiffness and strength of the frame increased greatly with the presence of the SBTD concrete slab. These test studies could promote the engineering design and application of the blind bolted CFST composite frames.
Cyclic testing of steel beam blind bolted to CFST column composite frames with SBTD concrete slabs
Wang, Jingfeng (Autor:in) / Li, Beibei (Autor:in) / Wang, Donghua (Autor:in) / Zhao, Chunfeng (Autor:in)
Engineering Structures ; 148 ; 293-311
25.06.2017
19 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Cyclic testing of steel beam blind bolted to CFST column composite frames with SBTD concrete slabs
Online Contents | 2017
|Cyclic Experimental Behavior of CFST Column to Steel Beam Frames with Blind Bolted Connections
Springer Verlag | 2018
|Cyclic Experimental Behavior of CFST Column to Steel Beam Frames with Blind Bolted Connections
Online Contents | 2018
|Pseudo-dynamic tests of assembly blind bolted composite frames to CFST columns
British Library Online Contents | 2017
|