Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Cyclic loading test for emulative precast concrete walls with partially reduced rebar section
Highlights To enhance the earthquake resistance of PC walls, two methods were studied. First, longitudinal rebars with partially reduced cross-sectional area were used. Second, a RC–PC hybrid wall was considered. Gap opening and shear slip at the panel joints were prevented by these methods. The seismic performance of the proposed PC walls was comparable to that of RC wall.
Abstract In conventional precast concrete (PC) walls subject to cyclic loading, the ductility and energy dissipation capacity are decreased by gap opening and shear slip at the panel joints. In this study, to enhance the earthquake resistance of emulative PC walls, two potential methods were studied. First, bonded or unbonded longitudinal rebars with partially reduced cross-sectional area were used at the plastic hinge zone. By using the reduced rebar area, the PC panel at the wall bottom was weakened to develop a plastic hinge zone in the PC panel rather than at the panel joints. Second, a RC–PC hybrid wall was considered, where cast-in-place concrete was used for the plastic hinge zone at the bottom of wall. Four specimens, including an ordinary RC wall, were tested under cyclic loading. The test results revealed that gap opening and shear slip at the panel joints were prevented by using the proposed methods. As a result, the ductility and energy dissipation of the proposed PC walls were comparable to those of the RC wall.
Cyclic loading test for emulative precast concrete walls with partially reduced rebar section
Highlights To enhance the earthquake resistance of PC walls, two methods were studied. First, longitudinal rebars with partially reduced cross-sectional area were used. Second, a RC–PC hybrid wall was considered. Gap opening and shear slip at the panel joints were prevented by these methods. The seismic performance of the proposed PC walls was comparable to that of RC wall.
Abstract In conventional precast concrete (PC) walls subject to cyclic loading, the ductility and energy dissipation capacity are decreased by gap opening and shear slip at the panel joints. In this study, to enhance the earthquake resistance of emulative PC walls, two potential methods were studied. First, bonded or unbonded longitudinal rebars with partially reduced cross-sectional area were used at the plastic hinge zone. By using the reduced rebar area, the PC panel at the wall bottom was weakened to develop a plastic hinge zone in the PC panel rather than at the panel joints. Second, a RC–PC hybrid wall was considered, where cast-in-place concrete was used for the plastic hinge zone at the bottom of wall. Four specimens, including an ordinary RC wall, were tested under cyclic loading. The test results revealed that gap opening and shear slip at the panel joints were prevented by using the proposed methods. As a result, the ductility and energy dissipation of the proposed PC walls were comparable to those of the RC wall.
Cyclic loading test for emulative precast concrete walls with partially reduced rebar section
Kang, Su-Min (Autor:in) / Kim, Ook-Jong (Autor:in) / Park, Hong-Gun (Autor:in)
Engineering Structures ; 56 ; 1645-1657
24.07.2013
13 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Cyclic loading test for emulative precast concrete walls with partially reduced rebar section
Online Contents | 2013
|In-Plane Quasi-Static Cyclic Tests on Emulative Precast Concrete Walls
Online Contents | 2018
|