Luminance and vertical eye illuminance thresholds for occupants’ visual comfort in daylit office environments
Abstract This paper investigates field measured visual parameters inside a daylit office space to define occupants' visual comfort thresholds, particularly for a view direction parallel to windows. Twelve human subjects performed a computer-based reading and typing task and provided subjective responses on various luminous environments, which were created by adjusting interior venetian blinds and electric lighting fixtures. A total of 120 different lighting conditions were tested and documented for both quantitative and qualitative analysis. High dynamic range photography was conducted to capture the luminance distributions of interior surfaces in addition to horizontal and vertical illuminance measurements by sensors. Statistical analysis of the collected data defined occupants’ visual comfort thresholds: a luminance of 2420 cd/m2 and luminance contrast ratio of 11.7. These new thresholds lie perfectly within the existing visual discomfort threshold ranges and confirm that a higher glare source luminance is tolerant in a view direction parallel to windows compared to view facing windows. A vertical eye illuminance threshold was also defined, but there are large discrepancies among the existing and newly defined thresholds. The collected subjective survey data also revealed 53%–60% evaluation accuracy rates of the existing glare indices. Daylight Glare Index and Unified Glare Rating metrics show the highest evaluation accuracy when daylight is the only light source. The CIE Glare Index metric shows the highest accuracy when both natural and electric lighting are introduced. Full understanding of visual comfort parameters and validation of the existing glare indices would help to achieve successful daylight harvesting in buildings.
Highlights Occupant's visual comfort parameters were investigated in a daylit office space. Various luminous environments were created by interior blinds and electric lights. Visual comfort thresholds were defined for luminance, contrast, and illuminance. Existing glare metrics were validated based on the collected human subject data.
Luminance and vertical eye illuminance thresholds for occupants’ visual comfort in daylit office environments
Abstract This paper investigates field measured visual parameters inside a daylit office space to define occupants' visual comfort thresholds, particularly for a view direction parallel to windows. Twelve human subjects performed a computer-based reading and typing task and provided subjective responses on various luminous environments, which were created by adjusting interior venetian blinds and electric lighting fixtures. A total of 120 different lighting conditions were tested and documented for both quantitative and qualitative analysis. High dynamic range photography was conducted to capture the luminance distributions of interior surfaces in addition to horizontal and vertical illuminance measurements by sensors. Statistical analysis of the collected data defined occupants’ visual comfort thresholds: a luminance of 2420 cd/m2 and luminance contrast ratio of 11.7. These new thresholds lie perfectly within the existing visual discomfort threshold ranges and confirm that a higher glare source luminance is tolerant in a view direction parallel to windows compared to view facing windows. A vertical eye illuminance threshold was also defined, but there are large discrepancies among the existing and newly defined thresholds. The collected subjective survey data also revealed 53%–60% evaluation accuracy rates of the existing glare indices. Daylight Glare Index and Unified Glare Rating metrics show the highest evaluation accuracy when daylight is the only light source. The CIE Glare Index metric shows the highest accuracy when both natural and electric lighting are introduced. Full understanding of visual comfort parameters and validation of the existing glare indices would help to achieve successful daylight harvesting in buildings.
Highlights Occupant's visual comfort parameters were investigated in a daylit office space. Various luminous environments were created by interior blinds and electric lights. Visual comfort thresholds were defined for luminance, contrast, and illuminance. Existing glare metrics were validated based on the collected human subject data.
Luminance and vertical eye illuminance thresholds for occupants’ visual comfort in daylit office environments
Suk, Jae Yong (Autor:in)
Building and Environment ; 148 ; 107-115
29.10.2018
9 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
British Library Online Contents | 2019
|British Library Conference Proceedings | 2003
|Visual Comfort Prediction Model of Daylit Office Space and Its Application in Architectural Design
Springer Verlag | 2024
|SKY LUMINANCE DISTRIBUTION MODEL FOR SIMULATIONOF DAYLIT ENVIRONMENT
British Library Conference Proceedings | 1999
|Visual comfort in the daylit luminous environment: Structural model for evaluation
British Library Online Contents | 1994