Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Investigation of liquid desiccant regenerator with heat recovery heat pipe system
AbstractTo evaluate and compare the regenerator of liquid desiccant dehumidification system (LDDS) without and with heat pipe heat exchanger (HPHE), this paper conducts performance analysis by hybrid heat transfer, mass transfer and heat recovery models, and the simulation results are then validated by the experimental results. 4 and 8 rows HPHE are compared to investigate the relationship between heat recovery rate and the additional fan energy consumption caused by the existence of HPHE. Effects of air mass flow rate on the regenerating and heat recovery performance are also discussed. The results show that the numerical computation is effective and accurate and the largest RE is only 10.87%. With heat recovery device, the regenerating performance is in general improved. The model predicted results reveal that the maximal net heat recovery ratios are 25% and 26.5% which contributes to 26.5% and 27% maximal energy saving for 4 and 8 rows, respectively, compared with regenerator without HPHE.
Investigation of liquid desiccant regenerator with heat recovery heat pipe system
AbstractTo evaluate and compare the regenerator of liquid desiccant dehumidification system (LDDS) without and with heat pipe heat exchanger (HPHE), this paper conducts performance analysis by hybrid heat transfer, mass transfer and heat recovery models, and the simulation results are then validated by the experimental results. 4 and 8 rows HPHE are compared to investigate the relationship between heat recovery rate and the additional fan energy consumption caused by the existence of HPHE. Effects of air mass flow rate on the regenerating and heat recovery performance are also discussed. The results show that the numerical computation is effective and accurate and the largest RE is only 10.87%. With heat recovery device, the regenerating performance is in general improved. The model predicted results reveal that the maximal net heat recovery ratios are 25% and 26.5% which contributes to 26.5% and 27% maximal energy saving for 4 and 8 rows, respectively, compared with regenerator without HPHE.
Investigation of liquid desiccant regenerator with heat recovery heat pipe system
Shen, Suping (Autor:in) / Cai, Wenjian (Autor:in) / Wang, Xinli (Autor:in) / Wu, Qiong (Autor:in) / Yon, Haoren (Autor:in)
Energy and Buildings ; 146 ; 353-363
21.04.2017
11 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Investigation of liquid desiccant regenerator with heat recovery heat pipe system
Online Contents | 2017
|Experimental investigation of an electrodialysis regenerator for liquid desiccant
Online Contents | 2013
|American Institute of Physics | 2013
|Hybrid solar still – Liquid desiccant regenerator and water distillation system
British Library Online Contents | 2019
|